Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Mar;187(3):191-201.
doi: 10.1007/s00066-010-2203-5. Epub 2011 Feb 24.

Cystatin C - a fast and reliable biomarker for glomerular filtration rate in head and neck cancer patients

Affiliations
Comparative Study

Cystatin C - a fast and reliable biomarker for glomerular filtration rate in head and neck cancer patients

Edwin Bölke et al. Strahlenther Onkol. 2011 Mar.

Abstract

Purpose: Determination of renal function is a prerequisite for planning therapy in cancer patients. Limitations of creatinine as marker for the glomerular filtration rate (GFR) led to the proposal of cystatin C as a more accurate biomarker especially in mild renal insufficiency or in patients with low muscle mass. We compared the accuracy of cystatin C- and creatinine-based equations to estimate GFR in head and neck cancer (HNC) patients receiving platinum-based radiochemotherapy.

Patients and methods: The study population consisted of 52 HNC patients (GFR range, 37-105 mL/min/1.73 m(2) complemented by 17 patients with known renal insufficiency (GFR range, 10-60 mL/min/1.73 m(2)). Intraclass correlation coefficients were calculated between the reference method (51)Cr-EDTA clearance and estimated GFR by creatinine clearance and equations based on creatinine (Cockroft-Gault, modification of diet in renal disease (MDRD), Wright) or cystatin C (Larsson, Dade-Behring, Hoek). In addition, sensitivity and specificity to discriminate GFR > 60 mL/min/1.73 m(2) were evaluated by receiver operating characteristic curve (ROC).

Results: The highest correlation coefficients were found for the cystatin C-based estimates in comparison with creatinine-based estimates or creatinine clearance, even though Bland-Altman plots revealed GFR overestimation for all equations tested. The cystatin C-based Hoek formula exhibited the highest overall precision and accuracy. GFR of < 60 mL/min/1.73 m(2) was assumed as a cut-off for chemotherapy. ROC analyses revealed the highest AUC to predict a GFR > 60 mL/min/1.73 m(2) for the creatinine-based Wright formula, closely followed by the MDRD formula and cystatin C-based equations of Larsson, Dade-Behring, and Hoek.

Conclusion: Cystatin C-based GFR estimates showed the overall strongest correlation to the reference method. Thus, we recommend cystatin C for GFR estimation in HNC patients as an alternative method to the estimated creatinine clearance in clinical practice.

PubMed Disclaimer

References

    1. Strahlenther Onkol. 2010 May;186(5):262-8 - PubMed
    1. Semin Oncol. 1992 Oct;19(5):521-8 - PubMed
    1. BMC Cancer. 2009 Mar 17;9:85 - PubMed
    1. Strahlenther Onkol. 2008 Nov;184(11):580-5 - PubMed
    1. Strahlenther Onkol. 2008 Jul;184(7):364-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources