Performance evaluation of a multiplex assay for future use in biomarker discovery efforts to predict body composition
- PMID: 21361852
- PMCID: PMC3749089
- DOI: 10.1515/CCLM.2011.122
Performance evaluation of a multiplex assay for future use in biomarker discovery efforts to predict body composition
Abstract
Background: Interest in biomarker patterns and disease has led to the development of immunoassays that evaluate multiple analytes in parallel while using little sample. However, there are no current standards for multiplex configuration, validation, and quality. Thus, validation by platform, population, and question of interest is recommended. We sought to determine the best blood fraction for multiplex evaluation of circulating biomarkers in post-menopausal women, and to explore body composition phenotype discrimination by biomarkers.
Methods: Archived serum and plasma samples from a sample of healthy post-menopausal women with the highest (n=9) and lowest (n=11) percent lean mass, as determined by dual-energy X-ray absorptiometry, were used to measure 90 analytes using bead-based, suspension multiplex assays. Replicates of serum and plasma were analyzed in a random selection of four of these individuals.
Results: Ninety percent of the analytes were detectable for ≥ 50% of samples; when limited to these well detected analytes, mean replicate correlations for serum and plasma were 0.87 and 0.85, respectively. Serum had lower error rates discriminating phenotypes; seven serum vs. two plasma analytes discriminated extreme body phenotypes.
Conclusions: Serum and plasma performed similarly for the majority of the analytes. Serum showed a slight advantage in predicting extreme body composition phenotypes in postmenopausal women using parallel evaluation of analytes.
Conflict of interest statement
The authors have no commercial, proprietary, or financial interest in the products or instruments described in this article.
Comment in
-
Multiplex protein assay performance/evaluation and the requirement for precision and correlation to clinical assays.Clin Chem Lab Med. 2011 Nov;49(11):1915-8. doi: 10.1515/CCLM.2011.683. Epub 2011 Aug 30. Clin Chem Lab Med. 2011. PMID: 21875396 No abstract available.
References
-
- Thomson CA, Arendell LA, Bruhn RL, Maskarinec G, Lopez AM, Wright NC, et al. Pilot study of dietary influences on mammographic density in pre- and postmenopausal Hispanic and non-Hispanic white women. Menopause. 2007;14:243–250. - PubMed
-
- Chen Z, Wang Z, Lohman T, Heymsfield SB, Outwater E, Nicholas JS, et al. Dual-energy X-ray absorptiometry is a valid tool for assessing skeletal muscle mass in older women. J Nutr. 2007;137:2775–2780. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources