Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 May 1;107(9):1365-74.
doi: 10.1016/j.amjcard.2010.12.048. Epub 2011 Mar 2.

Real-time three-dimensional transesophageal echocardiography for assessment of mitral valve functional anatomy in patients with prolapse-related regurgitation

Affiliations
Comparative Study

Real-time three-dimensional transesophageal echocardiography for assessment of mitral valve functional anatomy in patients with prolapse-related regurgitation

Giovanni La Canna et al. Am J Cardiol. .

Abstract

The aim of the study was to evaluate the additional diagnostic value of real-time 3-dimensional transesophageal echocardiography (RT3D-TEE) for surgically recognized mitral valve (MV) prolapse anatomy compared to 2-dimensional transthoracic echocardiography (2D-TTE), 2D-transesophageal echocardiography (2D-TEE), and real-time 3D-transthoracic echocardiography (RT3D-TTE). We preoperatively analyzed 222 consecutive patients undergoing repair for prolapse-related mitral regurgitation using RT3D-TEE, 2D-TEE, RT3D-TTE, and 2D-TTE. Multiplanar reconstruction was added to volume-rendered RT3D-TEE for quantitative prolapse recognition. The echocardiographic data were compared to the surgical findings. Per-patient analysis of RT3D-TEE identified prolapse in 204 patients more accurately (92%) than 2D-TEE (78%), RT3D-TTE (80%), and 2D-TTE (54%). Even among those 60 patients with complex prolapse (>1 segment localization or commissural lesions), RT3D-TEE correctly identified 58 (96.5%) compared to 42 (70%), 31 (52%), and 21 (35%) detected by 2D-TEE, RT3D-TTE, and 2D-TTE (p < 0.0001). Multiplanar reconstruction enabled RT3D-TEE to differentiate dominant (≥5-mm displacement) and secondary (2 to <5-mm displacement) prolapsed segments in agreement with surgically recognized dominant lesions (100%), but with a low predictive value (34%) for secondary lesions. In addition, owing to the identification of clefts and subclefts (indentations of MV tissue that extended ≥50% or <50% of the total leaflet height, respectively), RT3D-TEE accurately characterized the MV anatomy, including that which deviated from the standard nomenclature. In conclusion, RT3D-TEE provided more accurate mapping of MV prolapse than 2D imaging and RT3D-TTE, adding quantitative recognition of dominant and secondary lesions and MV anatomy details.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources