Diagnostic cutoff points for ¹²³I-MIBG myocardial scintigraphy in a Caucasian population with Parkinson's disease
- PMID: 21373765
- DOI: 10.1007/s00259-011-1754-8
Diagnostic cutoff points for ¹²³I-MIBG myocardial scintigraphy in a Caucasian population with Parkinson's disease
Abstract
Purpose: Molecular imaging with (123)I-metaiodobenzylguanidine (MIBG) has been used in Parkinson's disease (PD), but there is no consensual index to discriminate between normal and PD patients in the Caucasian population. The purpose of this study was to determine diagnostic cutoff points in the quantification of MIBG cardiac uptake in our population of PD patients. We have also calculated the reproducibility over a range of interpretation expertise.
Methods: The study included 14 PD patients and 14 normal age- and sex-matched controls. Heart to mediastinum ratios (H/M) were calculated at 15 min (H/M15m) and 4 h (H/M4h) post-injection by three observers with different interpretation expertise, one of whom drew the regions of interest at three different times. The intraobserver and interobserver reliability was calculated (interclass correlation coefficient and coefficient of variability). Diagnosis was estimated by maximizing the Youden index for H/M and washout ratios. Discrimination ability was assessed by the area under the curve (AUC). Sensitivity and specificity were reported, using our thresholds.
Results: The parameter with the best diagnostic accuracy was the H/M4h ratio, with a major AUC (0.976 area under the receiver-operating characteristic curve). The threshold was 1.43 with a 95% confidence interval of 1.37-1.50. Using this threshold, the sensitivity and specificity were 93 and 100%. The interobserver and intraobserver variabilities measuring this ratio were 3.2 and 3.1%, respectively.
Conclusion: The diagnostic cutoff point for (123)I-MIBG myocardial scintigraphy in a Caucasian population with PD was 1.43 for the H/M4h index, with a good sensitivity and specificity. The technique is easy to use, with a good reproducibility over a range of interpretation expertise.
Similar articles
-
Accuracy and cutoff values of delayed heart to mediastinum ratio with (123)I-metaiodobenzylguanidine cardiac scintigraphy for Lewy body disease diagnoses.BMC Neurol. 2015 May 15;15:83. doi: 10.1186/s12883-015-0338-9. BMC Neurol. 2015. PMID: 25971430 Free PMC article.
-
MIBG scintigraphy in differential diagnosis of Parkinsonism: a meta-analysis.Clin Auton Res. 2012 Feb;22(1):43-55. doi: 10.1007/s10286-011-0135-5. Epub 2011 Jul 27. Clin Auton Res. 2012. PMID: 21792729 Review.
-
131I-MIBG myocardial scintigraphy for differentiation of Parkinson's disease from multiple system atrophy or essential tremor in Chinese population.J Neurol Sci. 2017 Feb 15;373:48-51. doi: 10.1016/j.jns.2016.12.006. Epub 2016 Dec 7. J Neurol Sci. 2017. PMID: 28131225
-
Initial Versus Follow-up Sequential Myocardial 123I-MIBG Scintigraphy to Discriminate Parkinson Disease From Atypical Parkinsonian Syndromes.Clin Nucl Med. 2019 Apr;44(4):282-288. doi: 10.1097/RLU.0000000000002424. Clin Nucl Med. 2019. PMID: 30589669 Clinical Trial.
-
Neurological applications for myocardial MIBG scintigraphy.Nucl Med Rev Cent East Eur. 2013;16(1):35-41. doi: 10.5603/NMR.2013.0007. Nucl Med Rev Cent East Eur. 2013. PMID: 23677762 Review.
Cited by
-
Accuracy and cutoff values of delayed heart to mediastinum ratio with (123)I-metaiodobenzylguanidine cardiac scintigraphy for Lewy body disease diagnoses.BMC Neurol. 2015 May 15;15:83. doi: 10.1186/s12883-015-0338-9. BMC Neurol. 2015. PMID: 25971430 Free PMC article.
-
Sensitivity and specificity of cardiac metaiodobenzylguanidine scintigraphy in the early diagnosis of Parkinson's disease.Clin Auton Res. 2019 Dec;29(6):567-574. doi: 10.1007/s10286-018-0534-y. Epub 2018 Jun 5. Clin Auton Res. 2019. PMID: 29869732
-
MIBG scintigraphy in differential diagnosis of Parkinsonism: a meta-analysis.Clin Auton Res. 2012 Feb;22(1):43-55. doi: 10.1007/s10286-011-0135-5. Epub 2011 Jul 27. Clin Auton Res. 2012. PMID: 21792729 Review.
-
Potential diagnostic value of regional myocardial adrenergic imaging using (123)I-MIBG SPECT to identify patients with Lewy body diseases.Eur J Nucl Med Mol Imaging. 2015 Jun;42(7):1043-51. doi: 10.1007/s00259-015-2989-6. Epub 2015 Jan 28. Eur J Nucl Med Mol Imaging. 2015. PMID: 25626701
-
Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions.J Nucl Cardiol. 2012 Aug;19(4):752-62. doi: 10.1007/s12350-012-9539-4. Epub 2012 Jun 6. J Nucl Cardiol. 2012. PMID: 22669736 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical