Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;18(7):1222-33.
doi: 10.1007/s11356-010-0436-6. Epub 2011 Mar 4.

Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers

Affiliations

Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers

Alphanna-Akrivi Thomatou et al. Environ Sci Pollut Res Int. 2011 Aug.

Abstract

Purpose: Polar chemical integrative samplers (POCIS) were examined for their sampling efficiency of 12 pesticides and one metabolite commonly detected in surface waters. Laboratory-based calibration experiments of POCISs were conducted. The determined passive sampling rates were applied for the monitoring of pesticides levels in Lake Amvrakia, Western Greece. Spot sampling was also performed for comparison purposes.

Methods: Calibration experiments were performed on the basis of static renewal exposure of POCIS under stirred conditions for different time periods of up to 28 days. The analytical procedures were based on the coupling of POCIS and solid phase extraction by Oasis HLB cartridges with gas chromatography-mass spectrometry.

Results: The recovery of the target pesticides from the POCIS was generally >79% with relative standard deviation (RSD) <16%. The calibration results revealed an integrative uptake of all pesticides for 28 days and the calculated sampling rates ranged from 0.025 to 0.388 L day(-1) with RSD <29%. Low nanogram/liter levels of pesticides such as diazinon, alachlor, and s-metolachlor were detected during the monitoring campaign using both passive and spot sampling whereas higher concentrations were measured by spot sampling in most cases.

Conclusions: Passive sampling by POCIS provides a useful tool for the monitoring of pesticides in aquatic systems since integrative sampling at rates sufficient for analytical quantitation of ambient levels was observed. Calibration data are in demand for a greater number of compounds in order to extend the use in environmental monitoring.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mar Pollut Bull. 2009 Aug;58(8):1116-1122 - PubMed
    1. Anal Chim Acta. 2008 Jan 21;607(1):37-44 - PubMed
    1. Environ Toxicol Chem. 2007 Dec;26(12):2517-29 - PubMed
    1. Environ Pollut. 2006 Nov;144(1):296-307 - PubMed
    1. Environ Pollut. 2008 Nov;156(2):316-24 - PubMed

MeSH terms

LinkOut - more resources