Abstract
Purpose: Polar chemical integrative samplers (POCIS) were examined for their sampling efficiency of 12 pesticides and one metabolite commonly detected in surface waters. Laboratory-based calibration experiments of POCISs were conducted. The determined passive sampling rates were applied for the monitoring of pesticides levels in Lake Amvrakia, Western Greece. Spot sampling was also performed for comparison purposes.
Methods: Calibration experiments were performed on the basis of static renewal exposure of POCIS under stirred conditions for different time periods of up to 28 days. The analytical procedures were based on the coupling of POCIS and solid phase extraction by Oasis HLB cartridges with gas chromatography-mass spectrometry.
Results: The recovery of the target pesticides from the POCIS was generally >79% with relative standard deviation (RSD) <16%. The calibration results revealed an integrative uptake of all pesticides for 28 days and the calculated sampling rates ranged from 0.025 to 0.388 L day(-1) with RSD <29%. Low nanogram/liter levels of pesticides such as diazinon, alachlor, and s-metolachlor were detected during the monitoring campaign using both passive and spot sampling whereas higher concentrations were measured by spot sampling in most cases.
Conclusions: Passive sampling by POCIS provides a useful tool for the monitoring of pesticides in aquatic systems since integrative sampling at rates sufficient for analytical quantitation of ambient levels was observed. Calibration data are in demand for a greater number of compounds in order to extend the use in environmental monitoring.
Similar articles
-
Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration.Environ Sci Pollut Res Int. 2013 Jun;20(6):3679-87. doi: 10.1007/s11356-012-1284-3. Epub 2012 Nov 8. Environ Sci Pollut Res Int. 2013. PMID: 23135754
-
Development and Calibration of the Polar Organic Chemical Integrative Sampler (POCIS) for Neonicotinoid Pesticides.Environ Toxicol Chem. 2020 Jul;39(7):1325-1333. doi: 10.1002/etc.4729. Epub 2020 Jun 12. Environ Toxicol Chem. 2020. PMID: 32348590
-
Temperature dependence on the pesticide sampling rate of polar organic chemical integrative samplers (POCIS).Biosci Biotechnol Biochem. 2016 Oct;80(10):2069-75. doi: 10.1080/09168451.2016.1191329. Epub 2016 Jun 7. Biosci Biotechnol Biochem. 2016. PMID: 27305429
-
Review of atrazine sampling by polar organic chemical integrative samplers and Chemcatcher.Environ Toxicol Chem. 2018 Jul;37(7):1786-1798. doi: 10.1002/etc.4160. Epub 2018 Jun 7. Environ Toxicol Chem. 2018. PMID: 29687480 Review.
-
Application of the Polar Organic Chemical Integrative Sampler for Isolation of Environmental Micropollutants - A Review.Crit Rev Anal Chem. 2020;50(1):1-28. doi: 10.1080/10408347.2019.1565983. Epub 2019 Jun 15. Crit Rev Anal Chem. 2020. PMID: 31204504 Review.
Cited by
-
Active and passive sampling for the assessment of hydrophilic organic contaminants in a river basin-ecotoxicological risk assessment.Environ Sci Pollut Res Int. 2016 Mar;23(6):5577-91. doi: 10.1007/s11356-015-5760-4. Epub 2015 Nov 17. Environ Sci Pollut Res Int. 2016. PMID: 26573318
-
Determining the suitability of a polar organic chemical integrated sampler (POCIS) for the detection of pesticide residue in the Ishikawa River and its tributary in Osaka, Japan.J Pestic Sci. 2018 Feb 28;43(1):18-23. doi: 10.1584/jpestics.D17-063. J Pestic Sci. 2018. PMID: 30363146 Free PMC article.
-
Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration.Environ Sci Pollut Res Int. 2013 Jun;20(6):3679-87. doi: 10.1007/s11356-012-1284-3. Epub 2012 Nov 8. Environ Sci Pollut Res Int. 2013. PMID: 23135754
-
Development of quantitative structure-property relationship model for predicting the field sampling rate (Rs) of Chemcatcher passive sampler.Environ Sci Pollut Res Int. 2020 Apr;27(10):10415-10424. doi: 10.1007/s11356-020-07616-8. Epub 2020 Jan 14. Environ Sci Pollut Res Int. 2020. PMID: 31939012
-
The First Attempt at Non-Linear in Silico Prediction of Sampling Rates for Polar Organic Chemical Integrative Samplers (POCIS).Environ Sci Technol. 2016 Aug 2;50(15):7973-81. doi: 10.1021/acs.est.6b01407. Epub 2016 Jul 18. Environ Sci Technol. 2016. PMID: 27363449 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical