Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Jul;8(7):1046-9.
doi: 10.1016/j.hrthm.2011.02.034. Epub 2011 Mar 3.

The role of interpolation in PVC-induced cardiomyopathy

Affiliations
Comparative Study

The role of interpolation in PVC-induced cardiomyopathy

Hilal Olgun et al. Heart Rhythm. 2011 Jul.

Abstract

Background: Frequent premature ventricular complexes (PVCs) can cause cardiomyopathy. The mechanism is not known and may be multifactorial.

Objective: This study assessed the role of PVC interpolation in PVC-induced cardiomyopathy.

Methods: In 51 consecutive patients (14 women, age 49 ± 15 years, ejection fraction (EF) 0.49 ± 0.14) with frequent PVCs, 24-hour Holter recordings were performed. The amount of interpolation was determined and correlated with the presence of PVC-induced cardiomyopathy. In addition, parameters measured during an electrophysiology study were correlated with the Holter findings.

Results: Fourteen of the 21 patients (67%) with cardiomyopathy had interpolated PVCs, compared with only 6 of 30 patients (20%) without PVC-induced cardiomyopathy (P <.001). Patients with interpolated PVCs had a higher PVC burden than patients without interpolation (28% ± 12% vs. 15% ± 15%; P = .002). The burden of interpolated PVCs correlated with the presence of PVC cardiomyopathy (21% ± 30% vs. 4% ± 13%; P = .008). Both PVC burden and interpolation independently predicted PVC-induced cardiomyopathy (odds ratio 1.07, 95% confidence interval 1.01 to 1.13, P = .02; and odds ratio 4.43, 95% confidence interval 1.06 to 18.48, P = .04, respectively). The presence of ventriculoatrial block at a ventricular pacing cycle length of 600 ms correlated with the presence of interpolation (P = .004). Patients with interpolation had a longer mean ventriculoatrial block cycle length than patients without interpolated PVCs (520 ± 110 ms vs. 394 ± 92 ms; P = .01).

Conclusion: The presence of interpolated PVCs was predictive of the presence of PVC cardiomyopathy. Interpolation may play an important role in the generation of PVC-induced cardiomyopathy.

PubMed Disclaimer

Publication types

LinkOut - more resources