Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jan;6(1):47-57.
doi: 10.1016/j.fsigen.2011.01.011. Epub 2011 Mar 11.

Optimization and validation of a fast amplification protocol for AmpFlSTR® Profiler Plus® for rapid forensic human identification

Affiliations

Optimization and validation of a fast amplification protocol for AmpFlSTR® Profiler Plus® for rapid forensic human identification

Nancy Laurin et al. Forensic Sci Int Genet. 2012 Jan.

Abstract

The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR(®) Profiler Plus(®) to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4h to 26 min. No modification to the commercial AmpFlSTR(®) Profiler Plus(®) primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n-4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR(®) Profiler Plus(®) primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases.

PubMed Disclaimer

Publication types

LinkOut - more resources