Monitoring of direct anticoagulants
- PMID: 21404140
- DOI: 10.1007/s10354-011-0876-8
Monitoring of direct anticoagulants
Abstract
In recent years, new anticoagulants directly targeting individual components of the coagulation cascade have been developed. Although there is no need for routine coagulation monitoring with most of these agents, there are several clinical situations where a specific coagulation test should be available. Global coagulation tests react very sensitive to direct thrombin inhibitors or factor Xa inhibitors. However, with most agents, the effects on activated partial thromboplastin time (APTT) and prothrombin time (PT) are not linear and heterogeneous with respect to different reagents. In contrast, chromogenic assays show a good correlation to the pharmacokinetic of a specific agent.
Similar articles
-
Assessment of apixaban plasma levels by laboratory tests: suitability of three anti-Xa assays. A multicentre French GEHT study.Thromb Haemost. 2014 Feb;111(2):240-8. doi: 10.1160/TH13-06-0470. Epub 2013 Oct 31. Thromb Haemost. 2014. PMID: 24172843
-
Impact of dabigatran on a large panel of routine or specific coagulation assays. Laboratory recommendations for monitoring of dabigatran etexilate.Thromb Haemost. 2012 May;107(5):985-97. doi: 10.1160/TH11-11-0804. Epub 2012 Mar 22. Thromb Haemost. 2012. PMID: 22438031
-
Clinical laboratory measurement of direct factor Xa inhibitors: anti-Xa assay is preferable to prothrombin time assay.Thromb Haemost. 2010 Dec;104(6):1263-71. doi: 10.1160/TH10-05-0328. Epub 2010 Oct 26. Thromb Haemost. 2010. PMID: 20978714
-
Novel direct factor IIa and Xa inhibitors: mechanisms of action and preclinical studies.Curr Clin Pharmacol. 2012 Aug;7(3):149-65. doi: 10.2174/157488412800958695. Curr Clin Pharmacol. 2012. PMID: 22564123 Review.
-
Pharmacokinetic and Pharmacodynamic Drug Monitoring of Direct-Acting Oral Anticoagulants: Where Do We Stand?Ther Drug Monit. 2019 Apr;41(2):180-191. doi: 10.1097/FTD.0000000000000594. Ther Drug Monit. 2019. PMID: 30883512 Review.
Cited by
-
Fluorescence artifact correction in the thrombin generation assay: Necessity for correction algorithms in procoagulant samples.Res Pract Thromb Haemost. 2021 Mar 26;5(3):447-455. doi: 10.1002/rth2.12499. eCollection 2021 Mar. Res Pract Thromb Haemost. 2021. PMID: 33870030 Free PMC article.
-
Interconnectedness of global hemostasis assay parameters in simultaneously evaluated thrombin generation, fibrin generation and clot lysis in normal plasma.Thromb Res. 2016 Apr;140:132-139. doi: 10.1016/j.thromres.2015.11.023. Epub 2015 Nov 19. Thromb Res. 2016. PMID: 26632515 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical