Development of quality control system for flat-panel detectors
- PMID: 21409611
- DOI: 10.1007/s12194-011-0117-2
Development of quality control system for flat-panel detectors
Abstract
The characteristics of flat-panel detectors (FPD) are degraded by exposure to radiation. Degradation in a FPD progresses locally and has a nonlinear relationship to the radiation dose. In order to manage FPD systems properly, one must perform quality control (QC) such as evaluation of image degradation. However, no evaluation method for degradation has been established. In this paper, we first review the structure and degradation mechanism of FPDs, and then we propose a daily QC system for FPDs. To evaluate the degradation of FPDs, we investigated the number of defective pixels and lines, as well as the offset level of the pixel output. Furthermore, we developed daily QC software for FPD that can evaluate the image quality and is operationally simple. In the experiments, an indirect-conversion type FPD was evaluated by our proposed system. The offset level of FPD increased exponentially with X-ray exposure; no trends were seen for the number of defective pixels and defective lines. The required time for the evaluation of an FPD was about 1 min, and no special skills were needed for the analysis. These results indicate that our system may be useful for daily QC of FPDs.
Similar articles
-
A Rotatable Quality Control Phantom for Evaluating the Performance of Flat Panel Detectors in Imaging Moving Objects.J Digit Imaging. 2016 Feb;29(1):38-42. doi: 10.1007/s10278-015-9816-2. J Digit Imaging. 2016. PMID: 26264731 Free PMC article.
-
Quality control phantom for flat panel detector X-ray systems.Health Phys. 2013 Jan;104(1):97-101. doi: 10.1097/HP.0b013e3182659c72. Health Phys. 2013. PMID: 23192093
-
Flat-panel detectors: how much better are they?Pediatr Radiol. 2006 Sep;36 Suppl 2(Suppl 2):173-81. doi: 10.1007/s00247-006-0208-0. Pediatr Radiol. 2006. PMID: 16862412 Free PMC article. Review.
-
Difference in dose area product between analog image intensifier and digital flat panel detector in peripheral angiography and the effect of BMI.Rofo. 2013 Feb;185(2):153-9. doi: 10.1055/s-0032-1330276. Epub 2012 Nov 29. Rofo. 2013. PMID: 23196837
-
[Flat-panel detector technology -State-of-the-art and future prospects-].Igaku Butsuri. 2002;22(4):216-26. Igaku Butsuri. 2002. PMID: 12766267 Review. Japanese.
Cited by
-
Effect of frame rate on image quality in cardiology evaluated using an indirect conversion dynamic flat-panel detector.Radiol Phys Technol. 2024 Dec;17(4):947-954. doi: 10.1007/s12194-024-00845-3. Epub 2024 Sep 18. Radiol Phys Technol. 2024. PMID: 39292344
-
Simulation system for understanding the lag effect in fluoroscopic images.Radiol Phys Technol. 2013 Jul;6(2):273-80. doi: 10.1007/s12194-012-0196-8. Epub 2012 Dec 29. Radiol Phys Technol. 2013. PMID: 23271447
-
Investigation of image lag and modulation transfer function in fluoroscopy images obtained with a dynamic flat-panel detector.Radiol Phys Technol. 2013 Jul;6(2):367-74. doi: 10.1007/s12194-013-0210-9. Epub 2013 Apr 9. Radiol Phys Technol. 2013. PMID: 23568338
References
MeSH terms
LinkOut - more resources
Full Text Sources