Endothelial cell culture model for replication of physiological profiles of pressure, flow, stretch, and shear stress in vitro
- PMID: 21413699
- DOI: 10.1021/ac2002998
Endothelial cell culture model for replication of physiological profiles of pressure, flow, stretch, and shear stress in vitro
Abstract
The phenotype and function of vascular cells in vivo are influenced by complex mechanical signals generated by pulsatile hemodynamic loading. Physiologically relevant in vitro studies of vascular cells therefore require realistic environments where in vivo mechanical loading conditions can be accurately reproduced. To accomplish a realistic in vivo-like loading environment, we designed and fabricated an Endothelial Cell Culture Model (ECCM) to generate physiological pressure, stretch, and shear stress profiles associated with normal and pathological cardiac flow states. Cells within this system were cultured on a stretchable, thin (∼500 μm) planar membrane within a rectangular flow channel and subject to constant fluid flow. Under pressure, the thin planar membrane assumed a concave shape, representing a segment of the blood vessel wall. Pulsatility was introduced using a programmable pneumatically controlled collapsible chamber. Human aortic endothelial cells (HAECs) were cultured within this system under normal conditions and compared to HAECs cultured under static and "flow only" (13 dyn/cm(2)) control conditions using microscopy. Cells cultured within the ECCM were larger than both controls and assumed an ellipsoidal shape. In contrast to static control control cells, ECCM-cultured cells exhibited alignment of cytoskeletal actin filaments and high and continuous expression levels of β-catenin indicating an in vivo-like phenotype. In conclusion, design, fabrication, testing, and validation of the ECCM for culture of ECs under realistic pressure, flow, strain, and shear loading seen in normal and pathological conditions was accomplished. The ECCM therefore is an enabling technology that allows for study of ECs under physiologically relevant biomechanical loading conditions in vitro.
© 2011 American Chemical Society
Similar articles
-
[Rational utilization of a silicone tube flow chamber system].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2007 Oct;24(5):1061-4. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2007. PMID: 18027697 Chinese.
-
[Comparison of adhesion of different endothelial cells under shear stress load in the flow field in vitro].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011 Feb;28(1):157-62. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011. PMID: 21485205 Chinese.
-
Endothelial cell morphologic response to asymmetric stenosis hemodynamics: effects of spatial wall shear stress gradients.J Biomech Eng. 2010 Aug;132(8):081013. doi: 10.1115/1.4001891. J Biomech Eng. 2010. PMID: 20670062
-
Biorheological views of endothelial cell responses to mechanical stimuli.Biorheology. 2005;42(6):421-41. Biorheology. 2005. PMID: 16369082 Review.
-
Molecular basis of the effects of shear stress on vascular endothelial cells.J Biomech. 2005 Oct;38(10):1949-71. doi: 10.1016/j.jbiomech.2004.09.030. J Biomech. 2005. PMID: 16084198 Review.
Cited by
-
Microfluidic models of the human circulatory system: versatile platforms for exploring mechanobiology and disease modeling.Biophys Rev. 2021 Jul 14;13(5):769-786. doi: 10.1007/s12551-021-00815-8. eCollection 2021 Oct. Biophys Rev. 2021. PMID: 34777617 Free PMC article. Review.
-
Sphingosine-1-phosphate receptor subtype 2 signaling in endothelial senescence-associated functional impairments and inflammation.Curr Atheroscler Rep. 2015 May;17(5):504. doi: 10.1007/s11883-015-0504-y. Curr Atheroscler Rep. 2015. PMID: 25762236 Review.
-
Engineering a Bi-Conical Microchip as Vascular Stenosis Model.Micromachines (Basel). 2019 Nov 18;10(11):790. doi: 10.3390/mi10110790. Micromachines (Basel). 2019. PMID: 31752172 Free PMC article.
-
Building Blood Vessel Chips with Enhanced Physiological Relevance.Adv Mater Technol. 2023 Apr 6;8(7):2201778. doi: 10.1002/admt.202201778. Epub 2023 Feb 3. Adv Mater Technol. 2023. PMID: 37693798 Free PMC article.
-
Association of Early Atherosclerosis with Vascular Wall Shear Stress in Hypercholesterolemic Zebrafish.PLoS One. 2015 Nov 12;10(11):e0142945. doi: 10.1371/journal.pone.0142945. eCollection 2015. PLoS One. 2015. PMID: 26561854 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources