Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Dec;22(12):1446-53.
doi: 10.1111/j.1600-0501.2010.02140.x. Epub 2011 Mar 23.

Characteristics and dimensions of the Schneiderian membrane: a radiographic analysis using cone beam computed tomography in patients referred for dental implant surgery in the posterior maxilla

Affiliations

Characteristics and dimensions of the Schneiderian membrane: a radiographic analysis using cone beam computed tomography in patients referred for dental implant surgery in the posterior maxilla

Simone F M Janner et al. Clin Oral Implants Res. 2011 Dec.

Abstract

Objectives: To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Material and methods: The study included 143 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 168 CBCT images were taken using a limited field of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted coronal CBCT slices were analyzed with regard to the thickness and characteristics of the Schneiderian membrane in nine standardized points of reference. Factors such as age, gender, or status of the remaining dentition that could influence the dimensions of the Schneiderian membrane were evaluated using univariate and multivariate linear regression models.

Results: The thickness of the Schneiderian membrane exhibited a wide range, with a minimum value of 0.16 mm and a maximum value of 34.61 mm. The highest mean values, ranging from 2.16 to 3.11 mm, were found for the mucosa located in the mid-sagittal regions of the maxillary sinus. The most frequent mucosal findings diagnosed were flat thickenings of the Schneiderian membrane (62 positive findings, 37%). For the multivariate linear regression model, only gender had a statistically significant influence on the mean overall and mid-sagittal thickness of the sinus mucosa.

Conclusion: There is great interindividual variability in the thickness of the Schneiderian membrane. Gender seems to be the most important parameter influencing mucosal thickness in asymptomatic patients. Future studies are needed to assess the therapeutic and prognostic consequences of mucosal alterations in the maxillary sinus.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources