Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Mar 23;305(12):1210-6.
doi: 10.1001/jama.2011.338.

Implementation of a sensitive troponin I assay and risk of recurrent myocardial infarction and death in patients with suspected acute coronary syndrome

Affiliations

Implementation of a sensitive troponin I assay and risk of recurrent myocardial infarction and death in patients with suspected acute coronary syndrome

Nicholas L Mills et al. JAMA. .

Abstract

Context: Although troponin assays have become increasingly more sensitive, it is unclear whether further reductions in the threshold of detection for plasma troponin concentrations will improve clinical outcomes in patients with suspected acute coronary syndrome (ACS).

Objective: To determine whether lowering the diagnostic threshold for myocardial infarction (MI) with a sensitive troponin assay could improve clinical outcomes.

Design, setting, and patients: All consecutive patients admitted with suspected ACS to the Royal Infirmary of Edinburgh, Edinburgh, Scotland, before (n = 1038; February 1-July 31, 2008, during the validation phase) and after (n = 1054; February 1-July 31, 2009, during the implementation phase) lowering the threshold of detection for myocardial necrosis from 0.20 to 0.05 ng/mL with a sensitive troponin I assay were stratified into 3 groups (<0.05 ng/mL, 0.05-0.19 ng/mL, and ≥0.20 ng/mL). During the validation phase, only concentrations above the original diagnostic threshold of 0.20 ng/mL were reported to clinicians.

Main outcome measure: Event-free survival (recurrent MI and death) at 1 year in patients grouped by plasma troponin concentrations.

Results: Plasma troponin concentrations were less than 0.05 ng/mL in 1340 patients (64%), 0.05 to 0.19 ng/mL in 170 patients (8%), and 0.20 ng/mL or more in 582 patients (28%). During the validation phase, 39% of patients with plasma troponin concentrations of 0.05 to 0.19 ng/mL were dead or had recurrent MI at 1 year compared with 7% and 24% of those patients with troponin concentrations of less than 0.05 ng/mL (P < .001) or 0.20 ng/mL or more (P = .007), respectively. During the implementation phase, lowering the diagnostic threshold to 0.05 ng/mL was associated with a lower risk of death and recurrent MI (from 39% to 21%) in patients with troponin concentrations of 0.05 to 0.19 ng/mL (odds ratio, 0.42; 95% confidence interval, 0.24-0.84; P = .01).

Conclusions: In patients with suspected ACS, implementation of a sensitive troponin assay increased the diagnosis of MI and identified patients at high risk of recurrent MI and death. Lowering the diagnostic threshold of plasma troponin was associated with major reductions in morbidity and mortality.