Tissue concentrations of chlordanes in mice after long-term exposures to technical grade chlordane at indoor air levels
- PMID: 21432523
- PMCID: PMC2723552
- DOI: 10.1007/BF02932256
Tissue concentrations of chlordanes in mice after long-term exposures to technical grade chlordane at indoor air levels
Abstract
We determined concentrations of chlordanes (5 chlordane compounds and 2 metabolites) in tissues and organs of mice following a prolonged exposure to Chlordane (technical grade chlordane) at levels as low as those in indoor air.After exposure to 4.22-11.36 μ g/m(3) Chlordane (total of 5 compounds) in the air for 1-6 months, 6.44-13.00 ppm chlordanes (total of 7 compounds) were detected in mice (2 tissues and 6 organs). The adipose tissue among the 2 tissues / 6 organs examined contained the highest chlordanes. The ratio of the adipose tissue chlordanes to the liver chlordanes was approximately 5.6 times, followed by the muscle (0.9), lungs (0.4), kidneys (0.4), heart (0.3), spleen (0.2) and brain (0.1). In addition, trans-nonachlor, oxychlordane and heptachlorepoxide in chlordanes were at a high level.The level of Chlordane exposure (dose) and the level of chlordanes accumulation in each tissue or organ of the mice except for the heart were closely correlated (r=0.9388-0.7130), and showed a linear relationship. The tendency of chlordanes accumulation in light of the linear relationship was adipose ≫ liver ≥ muscle.Thus, even with a low level of Chlordane in indoor air, chlordanes may be steadily accumulated in the bodies of human residents with prolonged exposure similarly. The present findings suggest that it is necessary to investigate die risk of organochlorine chemicals contamination in indoor air at prolonged exposure.
Keywords: Accumulation; Chlordane; Exposure; Indoor air contamination; Long-term.
References
- 
    - None
- MatsumuraT, KametaniK.Studies on indoor air pollution (III) —The concentration of formaldehyde in indoor air—. Jpn J Publ Hlth 1983; 30: 303–8.
 
- 
    - None
- SuzukiS, NaganoS, SatohS. Measurement of chlorobenzenes concentration in outdoor and indoor air at Kanagawa prefecture. J Jpn Soc Air Pollu 1986; 21: 419–27.
 
- 
    - None
- MatsumuraT, MuramatsuS, KawadaH, SekitaH, OsadaE, KojimaS. Development of passive sampler for volatile organic compounds and its application to exposure measurement —p-dichlorobenzene—. Contam Control 1993; 30: 482–9.
 
- 
    - None
- HanaiY, ChenY, NakanishiJ. Indoor air pollution from construction materials. Bull Inst Environ Sci Tech 1996; 22: 1–10.
 
- 
    - None
- JitsunariF, AsakawaF, NakajimaT, ManabeY, GotohA. Investigation of indoor air contamination by chlordanes (II) Presence of indoor air contamination. Jpn J Publ Hlth 1987; 34: 302–8.
 
LinkOut - more resources
- Full Text Sources
- Research Materials
