Nuclear probes and intraoperative gamma cameras
- PMID: 21440694
- DOI: 10.1053/j.semnuclmed.2010.12.004
Nuclear probes and intraoperative gamma cameras
Abstract
Gamma probes are now an important, well-established technology in the management of cancer, particularly in the detection of sentinel lymph nodes. Intraoperative sentinel lymph node as well as tumor detection may be improved under some circumstances by the use of beta (negatron or positron), rather than gamma detection, because the very short range (∼ 1 mm or less) of such particulate radiations eliminates the contribution of confounding counts from activity other than in the immediate vicinity of the detector. This has led to the development of intraoperative beta probes. Gamma camera imaging also benefits from short source-to-detector distances and minimal overlying tissue, and intraoperative small field-of-view gamma cameras have therefore been developed as well. Radiation detectors for intraoperative probes can generally be characterized as either scintillation or ionization detectors. Scintillators used in scintillation-detector probes include thallium-doped sodium iodide, thallium- and sodium-doped cesium iodide, and cerium-doped lutecium orthooxysilicate. Alternatives to inorganic scintillators are plastic scintillators, solutions of organic scintillation compounds dissolved in an organic solvent that is subsequently polymerized to form a solid. Their combined high counting efficiency for beta particles and low counting efficiency for 511-keV annihilation γ-rays make plastic scintillators well-suited as intraoperative beta probes in general and positron probes in particular Semiconductors used in ionization-detector probes include cadmium telluride, cadmium zinc telluride, and mercuric iodide. Clinical studies directly comparing scintillation and semiconductor intraoperative probes have not provided a clear choice between scintillation and ionization detector-based probes. The earliest small field-of-view intraoperative gamma camera systems were hand-held devices having fields of view of only 1.5-2.5 cm in diameter that used conventional thallium-doped sodium iodide or sodium-doped cesium iodide scintillation detectors. Later units used 2-dimensional arrays (mosaics) of scintillation crystals connected to a position-sensitive photomultiplier tube and, more recently, semiconductors such as cadmium telluride or cadmium zinc telluride. The main problems with the early units were their very small fields of view and the resulting large number of images required to interrogate the surgical field and the difficulty in holding the device sufficiently still for the duration (up to 1 min) of the image acquisition. More recently, larger field-of-view (up to 5 × 5 cm) devices have developed which are attached to an articulating arm for easy and stable positioning. These systems are nonetheless fully portable and small enough overall to be accommodated in typical surgical suites.
Copyright © 2011 Elsevier Inc. All rights reserved.
Similar articles
-
Scintillation crystals for PET.J Nucl Med. 2000 Jun;41(6):1051-5. J Nucl Med. 2000. PMID: 10855634
-
Gamma cameras--state of the art.Med Instrum. 1979 May-Jun;13(3):161-4. Med Instrum. 1979. PMID: 440176
-
Experimental comparison of high-density scintillators for EMCCD-based gamma ray imaging.Phys Med Biol. 2012 Jul 21;57(14):4545-54. doi: 10.1088/0031-9155/57/14/4545. Epub 2012 Jun 22. Phys Med Biol. 2012. PMID: 22722678
-
Solid state detectors in nuclear medicine.Q J Nucl Med. 2002 Mar;46(1):3-7. Q J Nucl Med. 2002. PMID: 12072840 Review.
-
The intraoperative gamma probe: basic principles and choices available.Semin Nucl Med. 2000 Jan;30(1):33-48. doi: 10.1016/s0001-2998(00)80060-4. Semin Nucl Med. 2000. PMID: 10656242 Review.
Cited by
-
The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.Magn Reson Med. 2019 Nov;82(5):1946-1960. doi: 10.1002/mrm.27861. Epub 2019 Jun 23. Magn Reson Med. 2019. PMID: 31231885 Free PMC article.
-
The Utility of Intraoperative Handheld Gamma Camera for Detection of Sentinel Lymph Nodes in Melanoma.Nucl Med Mol Imaging. 2015 Dec;49(4):318-20. doi: 10.1007/s13139-015-0341-5. Epub 2015 May 13. Nucl Med Mol Imaging. 2015. PMID: 26550052 Free PMC article.
-
Molecular image-guided surgery in gynaecological cancer: where do we stand?Eur J Nucl Med Mol Imaging. 2024 Aug;51(10):3026-3039. doi: 10.1007/s00259-024-06604-1. Epub 2024 Jan 18. Eur J Nucl Med Mol Imaging. 2024. PMID: 38233609 Free PMC article. Review.
-
Intraoperative biophotonic imaging systems for image-guided interventions.Nanophotonics. 2019 Jan;8(1):99-116. doi: 10.1515/nanoph-2018-0134. Epub 2018 Dec 14. Nanophotonics. 2019. PMID: 31187017 Free PMC article.
-
Cerenkov imaging.Adv Cancer Res. 2014;124:213-34. doi: 10.1016/B978-0-12-411638-2.00006-9. Adv Cancer Res. 2014. PMID: 25287690 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources