Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 May;48(Pt 3):241-8.
doi: 10.1258/acb.2010.010219. Epub 2011 Mar 25.

Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department

Affiliations
Comparative Study

Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department

Sally J Aldous et al. Ann Clin Biochem. 2011 May.

Erratum in

  • Ann Clin Biochem. 2012 Mar;49(Pt 2):208. Flaws, Dylan Finlay [added]; Borowsky, Jennifer [added]

Abstract

Background: Current guidelines define acute myocardial infarction (AMI) by the rise and/or fall of cardiac troponin with ≥1 value above the 99th percentile. Past troponin assays have been unreliable at the lower end of the range. Highly sensitive assays have therefore been developed to increase the clinical sensitivity for detection of myocardial injury.

Methods: Three hundred and thirty-two patients with chest pain suggestive of AMI were prospectively recruited between November 2006 and April 2007. Serial blood samples were analysed to compare Roche Elecsys high sensitivity troponin T (hsTnT), Abbott Architect troponin I 3rd generation (TnI 3) and Roche Elecsys troponin T (TnT) for the diagnosis of AMI.

Results: One hundred and ten (33.1%) patients were diagnosed with AMI. Test performance for the diagnosis of AMI, as quantified by receiver operating characteristic area under the curve (95% confidence intervals) for baseline/follow-up troponins were as follows: hsTnT 0.90 (0.87-0.94)/0.94 (0.91-0.97), TnI 3 0.88 (0.84-0.92)/0.93 (0.90-0.96) and TnT 0.80 (0.74-0.85)/0.89 (0.85-0.94). hsTnT was superior to TnT (P < 0.001/0.013 at baseline/follow-up) but equivalent to TnI 3. For patients with a final diagnosis of AMI, baseline troponins were raised in more patients for hsTnT (83.6%) than TnI 3 (74.5%) and TnT (62.7%). A delta troponin of ≥20% increased the specificity of hsTnT from 80.6% to 93.7% but reduced sensitivity from 90.9% to 71.8%.

Conclusion: hsTnT was superior to TnT but equivalent to TnI 3 for the diagnosis of AMI. Serial troponin measurement increased test performance. hsTnT was the most likely to be raised at baseline in those with AMI. A delta troponin increases specificity but reduces sensitivity.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources