Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Jan;23(1):12-8.
doi: 10.1111/j.1600-0501.2010.02141.x. Epub 2011 Mar 28.

Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation

Affiliations
Comparative Study

Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation

Thomas C Truninger et al. Clin Oral Implants Res. 2012 Jan.

Abstract

Objectives: To test the fracture load of zirconia abutments with different types of implant-abutment connections after chewing simulation and to compare their bending moments to internally connected identical titanium abutments.

Materials and methods: Forty-eight identical customized zirconia abutments with different implant-abutment connections were fabricated for four different test groups: one-piece internal implant-abutment connection (BL; Straumann Bonelevel), two-piece internal implant-abutment connection (RS; Nobel Biocare Replace Select), external implant-abutment connection (B; Brånemark MK III), two-piece internal implant-abutment connection (SP; Straumann Standard Plus). Twelve titanium abutments with one-piece internal implant-abutment connection (T; Straumann Bonelevel) served as control group. After aging by means of thermocycling (5-50°C, 120 s) and chewing simulation (1,200,000 cycles, 49 N load, 1.67 Hz), static load was applied at a 30° angle to the palatal surface until failure. Bending moments were calculated for comparison of the groups. Data were analyzed descriptively and by performing the Kruskal-Wallis test with Bonferroni correction.

Results: The mean bending moments of the abutments were 714.1 ± 184.9 N cm (T), 331.7 ± 57.8 N cm (BL), 429.7 ± 62.8 N cm (RS), 285.8 ± 64.4 N cm (B) and 379.9 ± 59.1 N cm (SP). The bending moments of control group T were significantly higher than those of all other groups. The values of group RS were significantly higher than those of group B but within the value range of groups SP and BL.

Conclusion: The bending moments of the different tested types of zirconia abutments vary with different implant-abutment connections after chewing simulation. The use of a secondary metallic component might have a beneficial influence on the stability of zirconia abutments.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources