Implantable hemodynamic monitors
- PMID: 21459250
- DOI: 10.1016/j.ccl.2011.03.002
Implantable hemodynamic monitors
Abstract
The evaluation and management of volume status in patients with heart failure is a challenge for most clinicians. In addition, such an evaluation is possible only during a personal clinician-patient interface. The ability to acquire hemodynamic data continuously with the help of implanted devices with remote monitoring capability can provide early warning of heart failure decompensation and thus may aid in preventing hospitalizations for heart failure. The data obtained also may improve the understanding of the disease process. It is important for the clinician treating patients who have heart failure to become acquainted with this type of technology and learn to interpret and use these data appropriately. This article reviews the implantable hemodynamics monitors currently available.
Similar articles
-
Implantable hemodynamic monitors.Heart Fail Clin. 2009 Apr;5(2):261-70. doi: 10.1016/j.hfc.2008.11.005. Heart Fail Clin. 2009. PMID: 19249694 Review.
-
Integration of monitoring technology for heart failure.Curr Opin Cardiol. 2012 Mar;27(2):130-6. doi: 10.1097/HCO.0b013e3283502137. Curr Opin Cardiol. 2012. PMID: 22274575 Review.
-
Development of implantable devices for continuous ambulatory monitoring of central hemodynamic values in heart failure patients.Pacing Clin Electrophysiol. 2005 Jun;28(6):573-84. doi: 10.1111/j.1540-8159.2005.09558.x. Pacing Clin Electrophysiol. 2005. PMID: 15955193 Review.
-
Proactive monitoring: implications of implantable devices for future heart failure management.Crit Care Nurs Q. 2007 Oct-Dec;30(4):321-8. doi: 10.1097/01.CNQ.0000290365.65300.a9. Crit Care Nurs Q. 2007. PMID: 17873568 Review.
-
Remote patient monitoring in chronic heart failure.Cardiol Rev. 2013 May-Jun;21(3):141-50. doi: 10.1097/CRD.0b013e318276198b. Cardiol Rev. 2013. PMID: 23018667 Review.
Cited by
-
Local temperature elevation as a marker of spinal implant infection in an animal model.N Am Spine Soc J. 2021 Sep 3;7:100077. doi: 10.1016/j.xnsj.2021.100077. eCollection 2021 Sep. N Am Spine Soc J. 2021. PMID: 35141642 Free PMC article.
-
Cardiorenal syndrome: pathophysiology and potential targets for clinical management.Nat Rev Nephrol. 2013 Feb;9(2):99-111. doi: 10.1038/nrneph.2012.279. Epub 2012 Dec 18. Nat Rev Nephrol. 2013. PMID: 23247571 Review.
-
Implantable ultra-low pulmonary pressure monitoring system for fetal surgery.IEEE Trans Inf Technol Biomed. 2012 Nov;16(6):1208-15. doi: 10.1109/TITB.2012.2207399. Epub 2012 Jul 10. IEEE Trans Inf Technol Biomed. 2012. PMID: 22801521 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical