Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2011 Jun;58(6):560-8.
doi: 10.1007/s12630-011-9488-4. Epub 2011 Apr 5.

Brief review: Supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations

Affiliations
Review

Brief review: Supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations

Laura V Duggan et al. Can J Anaesth. 2011 Jun.

Abstract

Purpose: An airway exchange catheter (AEC) may be employed as a conduit for endotracheal tube placement and for oxygen insufflation or jet ventilation via its lumen. The recent barotrauma-related death of a young healthy patient receiving oxygen insufflated through an AEC prompted the Chief Coroner of Ontario to seek guidelines regarding their use. A literature search was undertaken using a number of search strategies to investigate both the efficacy and complications associated with supplying oxygen through an AEC.

Principal findings: No studies were found comparing either oxygen insufflation or jet-ventilation through an AEC to any standard forms of oxygen therapy. The only case series found using AEC jet ventilation reported that 11% of patients sustained pulmonary barotrauma. Thirteen case reports documented jet ventilation as being associated with pneumothorax, pneumomediastinum, pneumoperitoneum, cardiovascular collapse, and death. In three case series (totalling 76 adults and 20 children) using only oxygen insufflation, no complications were reported.

Conclusions: Jet ventilation through an AEC may be associated with a significant risk of barotrauma. Oxygen insufflation appears to be associated with a lower risk, but it is not risk-free. The authors caution against the use of an AEC to administer oxygen failing the proven benefit of its use over the use of standard oxygen therapies. Should a patient decompensate with an AEC in situ, tracheal re-intubation is the key management strategy. Supplemental oxygen can be provided using standard techniques prior to tracheal intubation or between attempts. Under emergency circumstances, oxygen insufflation or manual ventilation through an AEC may be considered provided vigilance for barotrauma is maintained and re-intubation is not delayed.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources