Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;18(4):285-93.
doi: 10.1007/s10140-011-0948-5. Epub 2011 Apr 7.

Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality

Affiliations
Free article

Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality

Christoph Karlo et al. Emerg Radiol. 2011 Aug.
Free article

Abstract

The purpose of this study is to assess the influence of different arm positioning techniques on thoracic and abdominal image quality and radiation dose of whole-body trauma CT (wbCT). One hundred and fifty polytrauma patients (104 male, mean age 47 ± 19) underwent wbCT with arms elevated above the head (group A, n=50), alongside the abdomen (group B, n=50), and on a pillow ventrally to the chest with both arms flexed (group C, n=50). Two blinded, independent observers measured image noise and rated image quality (scores 1-3) of the liver, aorta, spleen, spine, and lower lungs. Radiation dose parameters were noted, and the abdomens' anterior-posterior diameter and scan lengths were measured. Interreader agreements for image noise (r=0.86; p<0.001) and subjective image quality (k=0.71-0.84) were good. Noise was lower (p<0.05), image quality of the liver, aorta, spleen, and spine was higher, and radiation dose lower in group A than in groups B and C (p<0.001, each). Image quality of the spleen, liver, and aorta were higher in group C than in group B (p<0.05, each). No significant differences in scan length (p=0.61) were found among groups. Abdominal anterior-posterior diameter correlated significantly with noise (r=0.82; p<0.01) and dose (r=0.47; p<0.001). Estimated effective radiation doses were significantly (p<0.001) higher in groups B (21.2 mSv) and C (21.9 mSv) as compared to A (16.1 mSv). In wbCT for polytrauma patients, positioning of the arms above the head results in better image quality and lower radiation dose. Placing the flexed arms on a large pillow ventrally to the chest significantly improves image quality as compared to positioning alongside the abdomen.

PubMed Disclaimer

References

    1. Emerg Radiol. 2007 Feb;13(5):251-7 - PubMed
    1. Anaesthesist. 2002 Oct;51(10):835-42 - PubMed
    1. Emerg Radiol. 2006 Oct;13(1):25-30 - PubMed
    1. Emerg Med J. 2011 Apr;28(4):300-4 - PubMed
    1. Emerg Radiol. 2005 Apr;11(3):127-8 - PubMed