Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;21(8):1713-8.
doi: 10.1007/s00330-011-2116-4. Epub 2011 Apr 7.

Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

Affiliations

Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

C Messiou et al. Eur Radiol. 2011 Aug.

Abstract

Objectives: To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values.

Methods: The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow.

Results: The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054 + / -456 x 10⁻⁶mm²s⁻¹. An ADC threshold of 655 × 10(-6) mm(2)s(-1) separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm(-2).

Conclusion: The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm(-2) is optimal for imaging bone marrow.

PubMed Disclaimer

References

    1. Magn Reson Med. 2003 Jan;49(1):177-82 - PubMed
    1. Radiology. 2010 Nov;257(2):523-31 - PubMed
    1. J Magn Reson Imaging. 2004 Feb;19(2):222-8 - PubMed
    1. AJR Am J Roentgenol. 2007 Jun;188(6):1622-35 - PubMed
    1. Radiology. 2008 Dec;249(3):1017-25 - PubMed

Publication types

LinkOut - more resources