. 2011 Mar;22(3):408-17.
doi: 10.1007/s13361-010-0052-1. Epub 2011 Feb 1.

Protein-protein binding affinities in solution determined by electrospray mass spectrometry

Affiliations

Protein-protein binding affinities in solution determined by electrospray mass spectrometry

Jiangjiang Liu et al. J Am Soc Mass Spectrom. 2011 Mar.

Abstract

Electrospray ionization (ESI) allows the transfer of multi-protein complexes into the gas phase, thereby providing a simple approach for monitoring the stoichiometry of these noncovalent assemblies by mass spectrometry (MS). It remains unclear, however, whether the measured ion abundance ratios of free and bound species are suitable for determining solution-phase binding affinities (K(d) values). Many types of mass spectrometers employ rf-only quadrupoles as ion guides. This work demonstrates that the settings used for these devices are a key factor for ensuring uniform transmission behavior, which is a prerequisite for meaningful affinity measurements. Using bovine β-lactoglobulin and hemoglobin as model systems, it is demonstrated that under carefully adjusted conditions the "direct" ESI-MS approach is capable of providing K(d) values that are in good agreement with previously published solution-phase data. Of the several ion sources tested, a regular ESI emitter operated with pressure-driven flow at 1 μL min(-1) provided the most favorable results. Potential problems in these experiments include conformationally-induced differences in ionization efficiencies, inadvertent collision-induced dissociation, and ESI-induced clustering artifacts. A number of simple tests can be conducted to assess whether or not these factors are prevalent under the conditions used. In addition, the fidelity of the method can be scrutinized by performing measurements over a wide concentration range. Overall, this work supports the viability of the direct ESI-MS approach for determining binding affinities of protein-protein complexes in solution.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Anal Chem. 2004 Mar 15;76(6):1754-60 - PubMed
    1. J Am Soc Mass Spectrom. 2010 Feb;21(2):286-9 - PubMed
    1. J Biomol Tech. 1999 Dec;10(4):163-76 - PubMed
    1. Protein Sci. 2007 May;16(5):938-46 - PubMed
    1. Anal Bioanal Chem. 2010 Jun;397(3):967-72 - PubMed

Publication types

LinkOut - more resources