Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1990;5(2):60-7.

ECG-gated and static technetium-99m-SESTAMIBI planar myocardial perfusion imaging: a comparison with thallium-201 and study of observer variabilities

Affiliations
  • PMID: 2147553
Clinical Trial

ECG-gated and static technetium-99m-SESTAMIBI planar myocardial perfusion imaging: a comparison with thallium-201 and study of observer variabilities

J F Verzijlbergen et al. Am J Physiol Imaging. 1990.

Abstract

To assess the diagnostic accuracy of planar diastolic and static Technetium-99m-SESTAMIBI, myocardial perfusion imaging at rest and during exercise, was performed in 60 consecutive patients. The results were compared with coronary angiographic findings, obtained within 3 months of the exercise test and Thallium-201 images, obtained on the same day and to the same exercise level as Technetium-99m-SESTAMIBI exercise. Exact segmental concordance between static Technetium-99m-SESTAMIBI and Thallium-201 was 77% and between the diastolic images and Thallium-201 76%. Concordance between static and diastolic images was 92%. Nineteen percent of all 900 segments demonstrated ischemia with both static and diastolic Technetium-99m-SESTAMIBI and 20% with Thallium-201. Overall sensitivity to detect hemodynamically significant coronary artery disease with static Technetium-99m-SESTAMIBI was 86%, specificity 78%, with diastolic images 89% and 70% and with Thallium-201 89% and 78% (differences not significant). Vessel-specific comparative detection rates revealed no statistical significant differences between both radiopharmaceuticals as well. Intra-observer variability for the static images was 12%, for the diastolic images 21% and Thallium-201 14%. Inter-observer variability for the static images was 14%, diastolic images 24%, and Thallium-201 17%. Although the physical characteristics of Tc-SESTAMIBI enable to perform high-count density imaging and electrocardiographic gating, no significant differences are found when planar diastolic and static Technetium-99m-SESTAMIBI images are compared with Thallium-201 and are well within observer variabilities.

PubMed Disclaimer

Similar articles

Cited by