Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model
- PMID: 21484774
- DOI: 10.1002/bjs.7481
Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model
Abstract
Background: Combining hypothermic techniques, as a more practical approach to preservation, may enhance the condition of kidneys donated after cardiac death.
Methods: Porcine kidneys were retrieved after 10 min in situ warm ischaemia, then preserved by either 18 h static cold storage (CS), hypothermic machine perfusion for 18 h (HMP) or 14 h static CS followed by 4 h HMP (4HMP). Kidneys were reperfused for 3 h with oxygenated autologous blood on an isolated organ perfusion system to assess renal function and injury.
Results: Intrarenal resistance was significantly higher in the 4HMP group than in the CS and HMP groups: mean(s.d.) area under the curve (AUC) 8·48(2·97), 3·41(1·80) and 3·78(1·68) mmHg/min.h respectively (P = 0·011). Creatinine clearance was lower after 4HMP and CS: AUC 2·3(0·6) and 2·2(1·7) ml per min per 100g.h respectively versus 9·8(7·3) ml per min per 100g.h in the HMP group (P = 0·022). Levels of endothelin 1 were higher in the 4HMP and CS groups: mean(s.d.) 21·6(4·0) and 24·2(2·3) pg/ml respectively versus 11·4(4·6) pg/ml in the HMP group (P = 0·002). Morphological damage was increased in the 4HMP group.
Conclusion: This porcine kidney study demonstrated no advantage to the addition of 4 h of HMP after CS.
Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.