Image Gently: challenges for radiologic technologists when performing digital radiography in children
- PMID: 21491201
- DOI: 10.1007/s00247-010-1957-3
Image Gently: challenges for radiologic technologists when performing digital radiography in children
Abstract
The development of digital radiography (DR) has provided numerous benefits for pediatric imaging, including the ability to post-process images and to make images immediately available for access by care providers. However, DR presents several significant challenges for the radiologic technologists who are responsible for operating the equipment and producing high-quality images in children. This paper discusses those challenges, including lack of standardization among vendors, particularly with regard to the exposure indicator; lack of pediatric-specific educational materials and pediatric techniques; the need for manual technique instead of the use of automatic exposure control in smaller children; and complications related to field size, collimation and shielding in small children. Specific actions and design modifications that might facilitate the effective management of these challenges will be also described. The implementation of measures to promote the production of optimal images while minimizing radiation exposure requires cooperation and communication among imaging professionals, manufacturers and regulatory agencies.
Similar articles
-
Pediatric digital radiography education for radiologic technologists: current state.Pediatr Radiol. 2011 May;41(5):602-10. doi: 10.1007/s00247-010-1904-3. Epub 2011 Apr 14. Pediatr Radiol. 2011. PMID: 21491200
-
New exposure indicators for digital radiography simplified for radiologists and technologists.AJR Am J Roentgenol. 2012 Dec;199(6):1337-41. doi: 10.2214/AJR.12.8678. AJR Am J Roentgenol. 2012. PMID: 23169727
-
Optimizing digital radiography of children.Eur J Radiol. 2009 Nov;72(2):266-73. doi: 10.1016/j.ejrad.2009.03.003. Epub 2009 Apr 3. Eur J Radiol. 2009. PMID: 19345030
-
Image gently campaign back to basics initiative: ten steps to help manage radiation dose in pediatric digital radiography.AJR Am J Roentgenol. 2013 May;200(5):W431-6. doi: 10.2214/AJR.12.9895. AJR Am J Roentgenol. 2013. PMID: 23617510 Review.
-
Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.J Digit Imaging. 2009 Dec;22(6):656-66. doi: 10.1007/s10278-008-9150-z. Epub 2008 Sep 3. J Digit Imaging. 2009. PMID: 18769968 Free PMC article. Review.
Cited by
-
Female gonadal shielding with automatic exposure control increases radiation risks.Pediatr Radiol. 2018 Feb;48(2):227-234. doi: 10.1007/s00247-017-3996-5. Epub 2017 Oct 18. Pediatr Radiol. 2018. PMID: 29046919
-
European Guidelines for AP/PA chest X-rays: routinely satisfiable in a paediatric radiology division?Eur Radiol. 2016 Feb;26(2):495-505. doi: 10.1007/s00330-015-3836-7. Epub 2015 May 24. Eur Radiol. 2016. PMID: 26002133
-
Neonatal chest image quality addressed through training to enhance radiographer awareness.Health SA. 2018 Mar 26;23:1067. doi: 10.4102/hsag.v23i0.1067. eCollection 2018. Health SA. 2018. PMID: 31934372 Free PMC article.
-
Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center.Pediatr Cardiol. 2014 Jan;35(1):171-9. doi: 10.1007/s00246-013-0758-5. Epub 2013 Jul 20. Pediatr Cardiol. 2014. PMID: 23872908
-
Guidelines for anti-scatter grid use in pediatric digital radiography.Pediatr Radiol. 2014 Mar;44(3):313-21. doi: 10.1007/s00247-013-2824-9. Epub 2013 Nov 27. Pediatr Radiol. 2014. PMID: 24281685
References