[Mechanical loading and biomechanical problems of total joint surface replacement of the tibial plateau]
- PMID: 2149240
- DOI: 10.1055/s-2008-1040012
[Mechanical loading and biomechanical problems of total joint surface replacement of the tibial plateau]
Abstract
Recent reports of fractures of the tibial component of total knee prostheses have raised the question of their long term endurance. The mechanical load for the tibial plateau consists of the two forces deriving from the condyles of the femur. As the collateral and crucial ligaments always allow a little play for the femoral and tibial components, the location of the load of the condyles on the tibial plateau is either on the medial or lateral side depending on minor disturbances during gait. For a tibial plateau with only little medullary anchorage this load pattern means an alternating induction of compression and tensile stresses for the underlying bone. This alternating stress pattern is discussed as a possible mechanism of aseptic loosening of such tibial components. For two cases of such aseptic loosening and consecutive fracture of the tibial plateau of a metal backed unconstrained sledge knee prosthesis the radiologic findings are demonstrated and correlated to the biomechanical mechanisms described. It is demonstrated that the structural endurance of the tibial plateau does not withstand the mechanical stresses of such a situation of aseptic loosening. In these cases further loosening or fracture of the tibial plateau results.
Similar articles
-
[Mechanical stress on the osseous tibial plateau in complement joint surface replacement--a finite element analysis].Z Orthop Ihre Grenzgeb. 1991 Sep-Oct;129(5):389-92. doi: 10.1055/s-2008-1040262. Z Orthop Ihre Grenzgeb. 1991. PMID: 1836693 German.
-
Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions.J Biomech. 2010 Apr 19;43(6):1074-80. doi: 10.1016/j.jbiomech.2009.12.006. Epub 2010 Mar 1. J Biomech. 2010. PMID: 20189576
-
Mechanical strength of trabecular bone at the knee.Dan Med Bull. 1988 Aug;35(4):345-65. Dan Med Bull. 1988. PMID: 3048922 Review.
-
[Uncemented knee prosthesis. Results apropos of 58 cases with a minimum of 5-year follow-up].Rev Chir Orthop Reparatrice Appar Mot. 1995;81(6):505-13. Rev Chir Orthop Reparatrice Appar Mot. 1995. PMID: 8560021 French.
-
Pop-top tibial component: elimination of back-side wear with potential modularity.Surg Technol Int. 2004;13:253-60. Surg Technol Int. 2004. PMID: 15744698 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials