Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms
- PMID: 21498369
- DOI: 10.1258/ar.2010.100229
Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms
Abstract
Background: The morphological analysis prior to endovascular abdominal aneurysm repair (EVAR) plays an important role in long-term outcomes. Post-imaging analysis of computed tomographic angiography (CTA) by three-dimensional reconstruction with central lumen line detection (CLL 3D-CTA) enables measurements to be made in orthogonal slices. This might be more precise than equal post-imaging analysis in axial slices by two-dimensional computed tomographic angiography (2D-CTA).
Purpose: To evaluate the intra- and interobserver variability of CLL 3D-CTA and 2D-CTA post-imaging analysis methods and the agreement between them in pre-EVAR suitability analysis of patients with abdominal aortic aneurysm (AAA).
Material and methods: Anonymized CTA data-sets from 70 patients with AAA were analyzed retrospectively. Length measurements included proximal and distal aortic neck lengths and total distance from the lower renal artery to the higher iliac bifurcation. Width measurements included proximal and distal neck diameters, maximum AAA diameter and common iliac diameters just above the iliac bifurcations. The measurements were performed in random order by two vascular surgeons, twice per method with 1-month interval between readings. In the CLL 3D-CTA method we used semi-automated CLL detection by software and manual measurements on CTA slices perpendicular to CLL. The equal measurements in 2D-CTA were performed manually on axial CTA slices using a DICOM viewer workstation. The intra- and interobserver variability, as well as the agreement between the two methods were assessed by Bland-Altman test and bivariate correlation analysis.
Results: The intraobserver variability was significantly higher in 2D-CTA measurements for both readers. The interobserver variability was significant in 2D-CTA measurements of proximal neck dimensions while the agreement in CLL 3D-CTA analysis between the two readers was excellent in all studied parameters. The agreement between the two suitability analysis techniques was poor for both readers, especially in measurements of proximal neck's dimensions and in total aortoiliac length (p = 0.001).
Conclusion: In pre-EVAR morphological evaluation of AAAs the CLL-3D CTA post-imaging analysis has better intra- and interobserver correlation than 2D-CTA and might represent a useful tool for the proper selection of endograft's type and size.
Similar articles
-
Intraobserver and interobserver variability of 64-row computed tomography abdominal aortic aneurysm neck measurements.J Vasc Surg. 2007 Feb;45(2):263-8. doi: 10.1016/j.jvs.2006.10.004. J Vasc Surg. 2007. PMID: 17264000
-
Influence of computed tomography angiography reconstruction software on anatomic measurements and endograft component selection for endovascular abdominal aortic aneurysm repair.J Vasc Surg. 2014 May;59(5):1224-31.e1-3. doi: 10.1016/j.jvs.2013.11.003. Epub 2014 Jan 16. J Vasc Surg. 2014. PMID: 24439321
-
Multidetector CT angiography versus digital subtraction angiography for aortoiliac length measurements prior to endovascular AAA repair.J Endovasc Ther. 2004 Oct;11(5):527-34. doi: 10.1583/03-1172.1. J Endovasc Ther. 2004. PMID: 15482025
-
Endovascular repair of abdominal aortic aneurysms: CTA evaluation of contraindications.Abdom Imaging. 2006 Nov-Dec;31(6):722-31. doi: 10.1007/s00261-005-0399-0. Abdom Imaging. 2006. PMID: 16447080 Review.
-
Imaging of the endoleak after endovascular aneurysm repair procedure by using multidetector computer tomography angiography.J Cardiovasc Surg (Torino). 2009 Aug;50(4):515-26. J Cardiovasc Surg (Torino). 2009. PMID: 19734835 Review.
Cited by
-
Long-Term Remodeling of Aortoiliac Vessels After Standard EVAR, the Reality to Be Considered.J Clin Med. 2025 Aug 8;14(16):5626. doi: 10.3390/jcm14165626. J Clin Med. 2025. PMID: 40869452 Free PMC article.
-
The use of virtual resources in preoperative preparation of infrarenal aneurysms: exploring the OsiriX's potential.Rev Bras Cir Cardiovasc. 2014 Apr-Jun;29(2):279-84. doi: 10.5935/1678-9741.20140065. Rev Bras Cir Cardiovasc. 2014. PMID: 25140480 Free PMC article.
-
Repair of abdominal aortic aneurysms: preoperative imaging and evaluation.Cardiovasc Diagn Ther. 2018 Apr;8(Suppl 1):S157-S167. doi: 10.21037/cdt.2018.01.01. Cardiovasc Diagn Ther. 2018. PMID: 29850427 Free PMC article. Review.
-
The Long-Term Progression of Aneurysmal Disease in Common Iliac Arteries After Standard EVAR and Its Clinical Implications.Int J Vasc Med. 2024 Nov 29;2024:4229582. doi: 10.1155/ijvm/4229582. eCollection 2024. Int J Vasc Med. 2024. PMID: 39650203 Free PMC article.
-
Early Results of Elective Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms With the MinosTM Stent-Graft System.J Endovasc Ther. 2025 Feb;32(1):225-232. doi: 10.1177/15266028231172379. Epub 2023 May 11. J Endovasc Ther. 2025. PMID: 37166154 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical