. 2011 Jul;152(1):16-21.e2.
doi: 10.1016/j.ajo.2011.01.009. Epub 2011 Apr 19.

Femtosecond laser vs mechanical microkeratome for hyperopic laser in situ keratomileusis

Affiliations
Comparative Study

Femtosecond laser vs mechanical microkeratome for hyperopic laser in situ keratomileusis

Raquel Gil-Cazorla et al. Am J Ophthalmol. 2011 Jul.

Abstract

Purpose: To compare the outcomes of laser in situ keratomileusis (LASIK) performed with a femtosecond laser vs a mechanical microkeratome for the correction of low to moderate hyperopia.

Design: Retrospective, nonrandomized, interventional, comparative case series.

Methods: settings: Vissum Santa Hortensia, Madrid, Spain.study population and procedures: Patients who had undergone LASIK to correct their hyperopia using the 60-kHz IntraLase femtosecond laser were compared to age- and refraction-matched patients in whom the Moria M2 microkeratome was used. Visual and refractive results 3 months postoperatively were compared between both groups.

Results: A total of 144 eyes were analyzed (72 in each group). Mean preoperative sphere was +3.45 ± 1.0 diopters (D) in the IntraLase group vs +3.18 ± 1.3 D in the M2 group (P = .1). Results 3 months postoperatively were: mean residual sphere, +0.44 ± 0.6D vs +0.72 ± 0.8 D (P = .02), respectively; uncorrected visual acuity (UCVA), 0.89 ± 0.2 vs 0.80 ± 0.2 (P = .04); best spectacle-corrected visual acuity (BSCVA), 0.96 ± 0.2 vs 0.92 ± 0.2 (P = .2); safety index, 0.97 ± 0.1 vs 0.98 ± 0.1 (P = .5); efficacy index, 0.89 ± 0.2 vs 0.84 ± 0.2 (P = .3).

Conclusions: Hyperopic LASIK performed with the IntraLase femtosecond laser seems to achieve better refractive results 3 months after the surgery compared to the M2 microkeratome, without significant differences in safety between both procedures.