Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 May;196(5):W592-7.
doi: 10.2214/AJR.10.5486.

Reliability of renal length measurements made with ultrasound compared with measurements from helical CT multiplanar reformat images

Affiliations
Comparative Study

Reliability of renal length measurements made with ultrasound compared with measurements from helical CT multiplanar reformat images

David B Larson et al. AJR Am J Roentgenol. 2011 May.

Abstract

Objective: The purpose of this article is to determine the reliability of sonographic renal length measurements compared with measurements obtained from helical CT multiplanar reformat images and compared with standard renal growth curves.

Materials and methods: A retrospective review was performed of 76 subjects who underwent both renal ultrasound and abdominal CT within 2 weeks of one another. Renal lengths were measured using oblique coronal reformat images of helically acquired CT data by two observers on two occasions. Intraobserver and interobserver error for these measurements were calculated. Ultrasound renal length measurements were compared with CT measurements. Measurement variation was compared with standard renal growth curves.

Results: The mean (± SD) of the absolute value of interobserver error of CT measurements was 0.9 ± 0.8 mm. Compared with CT, individual ultrasound measurements underestimated renal length by 1.5 ± 5.6 mm on average, with a 95% CI of -12.5 to 9.5 mm. When the maximum of three ultrasound renal length measurements was used, the SD was 4.7 mm, with a 95% CI of -8.2 to 10.1 mm of the reported renal length. This corresponds to greater or less than 3.3 years of normal renal growth.

Conclusion: Lack of renal growth can be asserted only when renal length falls below the growth curve, taking into account the corresponding measurement error limits, which we found to be greater or less than 9.3 mm. If the follow-up measurement falls within these limits, one should not infer lack of appropriate renal growth, even if the renal length measurement decreases or remains unchanged for up to 3 years.

PubMed Disclaimer

Publication types

LinkOut - more resources