. 2011 Jul;400(10):3505-15.
doi: 10.1007/s00216-011-4997-0. Epub 2011 Apr 24.

Development and validation of a rapid LC-ESI-MS/MS method for quantification of fluoxetine and its application to MS binding assays

Affiliations

Development and validation of a rapid LC-ESI-MS/MS method for quantification of fluoxetine and its application to MS binding assays

Marielle Hess et al. Anal Bioanal Chem. 2011 Jul.

Abstract

In the present study, a rapid and sensitive LC-ESI-MS/MS method for quantification of (S)-fluoxetine as a native marker in mass spectrometry (MS) binding assays addressing the human serotonin transporter (hSERT) was developed and validated. The concept of MS binding assays based on mass spectrometric quantification of a nonlabeled marker recently introduced by us represents a promising alternative to conventional radioligand binding without the drawbacks inherently connected with radioisotope labeling. For high-performance liquid chromatography (HPLC), a 20 × 2-mm RP-18 column with a mobile phase composed of acetonitrile and ammonium bicarbonate buffer (5 mmol L(-1), pH 9.5) at a ratio of 80:20 (v/v) and a flow rate of 800 μL min(-1) in an isocratic mode were used, resulting in a chromatographic cycle time of 60 s. Employing [(2)H(5)]fluoxetine as internal standard enabled ESI-MS/MS quantification of (S)-fluoxetine between 3 nmol L(-1) and 50 pmol L(-1) (LLOQ) in matrix obtained from binding experiments without the need of any sample preparation. Validation of the method showed that linearity, intra-, and inter-batch accuracy as well as precision meet the requirements of the FDA guidance for bioanalytical method validation. Considering sensitivity and speed, the established method is clearly superior to those published for biological matrices so far. Furthermore, the method was transferred to other RP-18 columns of different lengths and respective validation experiments demonstrated its versatility and chromatographic robustness. Finally, the newly developed method was successfully applied to MS binding assays for hSERT. The affinity determined for (S)-fluoxetine in saturation experiments was in good agreement with literature data obtained in respective radioligand binding assays.