Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2011 Apr;18(2):131-43.
doi: 10.1583/10-3233MR.1.

Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: results from the RESTORE Patient Registry

Collaborators, Affiliations
Multicenter Study

Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: results from the RESTORE Patient Registry

Burkhart Zipfel et al. J Endovasc Ther. 2011 Apr.

Abstract

Purpose: To evaluate the safety and performance of Relay stent-grafts in patients with acute or chronic aortic dissections.

Methods: Patients with types A or B aortic dissections suitable for treatment with Relay stent-grafts and followed for 2 years after thoracic endovascular aortic repair (TEVAR) were identified from a company-sponsored registry database established in January 2006. Ninety-one consecutive patients (69 men; mean age 65 years) underwent TEVAR with Relay stent-grafts for dissection. Most patients (76, 84%) had type B dissections; 61 of all patients were classified as chronic and 30 as acute.

Results: The technical success rate was 95% (97% in acute, 95% in chronic, and 93% in type B dissections). The type I endoleak rate was 7% (7% in acute and 8% in chronic dissections); all occurred in patients with type B dissections. Paraplegia, paraparesis, and stroke occurred in 4, 1, and 2 patients, respectively; 2 cases of paraplegia occurred in patients with acute type B dissections. Thirty-day mortality was 8% (13% in acute and 5% in chronic dissections); all deaths occurred in patients with type B dissections. The 2-year survival rate was 82% in the overall population and 84% in patients with type B dissections.

Conclusion: The combination of Relay's features, such as stent conformability, radial force, atraumatic design, and controlled deployment and fixation, may contribute to the safety of the Relay stent-grafts for the treatment of thoracic aortic dissections, including acute and chronic type B dissections.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources