Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Aug;30(8):870-8.
doi: 10.1016/j.healun.2011.03.005. Epub 2011 Apr 29.

Inhaled nitric oxide after left ventricular assist device implantation: a prospective, randomized, double-blind, multicenter, placebo-controlled trial

Affiliations
Randomized Controlled Trial

Inhaled nitric oxide after left ventricular assist device implantation: a prospective, randomized, double-blind, multicenter, placebo-controlled trial

Evgenij Potapov et al. J Heart Lung Transplant. 2011 Aug.

Abstract

Background: Used frequently for right ventricular dysfunction (RVD), the clinical benefit of inhaled nitric oxide (iNO) is still unclear. We conducted a randomized, double-blind, controlled trial to determine the effect of iNO on post-operative outcomes in the setting of left ventricular assist device (LVAD) placement.

Methods: Included were 150 patients undergoing LVAD placement with pulmonary vascular resistance ≥ 200 dyne/sec/cm(-5). Patients received iNO (40 ppm) or placebo (an equivalent concentration of nitrogen) until 48 hours after separation from cardiopulmonary bypass, extubation, or upon meeting study-defined RVD. For ethical reasons, crossover to open-label iNO was allowed during the 48-hour treatment period if RVD criteria were met.

Results: RVD criteria were met by 7 of 73 patients (9.6%; 95% confidence interval, 2.8-16.3) in the iNO group compared with 12 of 77 (15.6%; 95% confidence interval, 7.5-23.7) who received placebo (p = 0.330). Time on mechanical ventilation decreased in the iNO group (median days, 2.0 vs 3.0; p = 0.077), and fewer patients in the iNO group required an RVAD (5.6% vs 10%; p = 0.468); however, these trends did not meet statistical boundaries of significance. Hospital stay, intensive care unit stay, and 28-day mortality rates were similar between groups, as were adverse events. Thirty-five patients crossed over to open-label iNO (iNO, n = 15; placebo, n = 20). Eighteen patients (iNO, n = 9; placebo, n = 9) crossed over before RVD criteria were met.

Conclusions: Use of iNO at 40 ppm in the perioperative phase of LVAD implantation did not achieve significance for the primary end point of reduction in RVD. Similarly, secondary end points of time on mechanical ventilation, hospital or intensive care unit stay, and the need for RVAD support after LVAD placement were not significantly improved.

PubMed Disclaimer

Publication types

MeSH terms