Diagnostic accuracy of Kato-Katz and FLOTAC for assessing anthelmintic drug efficacy
- PMID: 21532740
- PMCID: PMC3075226
- DOI: 10.1371/journal.pntd.0001036
Diagnostic accuracy of Kato-Katz and FLOTAC for assessing anthelmintic drug efficacy
Abstract
Background: Sensitive diagnostic tools are required for an accurate assessment of prevalence and intensity of helminth infections in areas undergoing regular deworming, and for monitoring anthelmintic drug efficacy. We compared the diagnostic accuracy of the Kato-Katz and FLOTAC techniques in the frame of a drug efficacy trial.
Methodology/principal findings: Stool samples from 343 Zanzibari children were subjected to duplicate Kato-Katz thick smears and the FLOTAC basic technique in a baseline screening in early 2009. The FLOTAC showed a higher sensitivity than the Kato-Katz method for the diagnosis of Trichuris trichiura (95% vs. 88%, p = 0.012) and Ascaris lumbricoides (88% vs. 68%, p = 0.098), but a lower sensitivity for hookworm diagnosis (54% vs. 81%, p = 0.006). Considering the combined results from both methods as 'gold' standard, the prevalences of T. trichiura, hookworm and A. lumbricoides were 71% (95% confidence interval (CI): 66-75%), 22% (95% CI: 17-26%) and 12% (95% CI: 8-15%), respectively. At follow-up, 3-5 weeks after 174 among the 269 re-examined children were administered anthelmintic drugs, we observed cure rates (CRs) against A. lumbricoides, hookworm and T. trichiura of 91% (95% CI: 80-100%), 61% (95% CI: 48-75%) and 41% (95% CI: 34-49%), respectively, when using the Kato-Katz method. FLOTAC revealed lower CRs against A. lumbricoides (83%, 95% CI: 67-98%) and T. trichiura (36%, 95% CI: 29-43%), but a higher CR against hookworm (69%, 95% CI: 57-82%). These differences, however, lacked statistical significance. Considerable differences were observed in the geometric mean fecal egg counts between the two methods with lower egg reduction rates (ERRs) determined by FLOTAC.
Conclusion/significance: Our results suggest that the FLOTAC technique, following further optimization, might become a viable alternative to the Kato-Katz method for anthelmintic drug efficacy studies and for monitoring and evaluation of deworming programs. The lower CRs and ERRs determined by FLOTAC warrant consideration and could strategically impact future helminth control programs.
Conflict of interest statement
GC is the inventor and current patent holder of the FLOTAC apparatus. In case the current broad-scale validation of the FLOTAC technique will be successful, the method will be licensed free of charge to the WHO and interested public non-commercial research centers. None of the other authors has any conflict of interest concerning the work reported in this paper.
Figures
References
-
- Keiser J, Utzinger J. The drugs we have and the drugs we need against major helminth infections. Adv Parasitol. 2010;73:197–230. - PubMed
-
- WHO. Prevention and control of schistosomiasis and soil-transmitted helminthiasis: report of a WHO expert committee. WHO Tech Rep Ser. 2002;912:1–57. - PubMed
-
- WHO. Soil-transmitted helminthiasis. Wkly Epidemiol Rec. 2008;83:237–252. - PubMed