Arthroscopic rotator cuff repair: suture anchor properties, modes of failure and technical considerations
Abstract
Rotator cuff injury and tears are a common source of shoulder pain, particularly among the elderly. Arthroscopic repair has now become the mainstay in the treatment of significant injuries that have failed conservative therapy. Compared with the traditional open technique, arthroscopic repair offers patients smaller incisions and less soft-tissue trauma, which result in improved postoperative pain and rehabilitation. The advances that have made arthroscopic repairs a reality includes improvement in arthroscopic rotator cuff instrumentation, particularly suture anchors. Suture anchors are used to reattach the torn rotator cuff tissue back onto the bone. Current rotator cuff anchors vary by design, anchor composition and suture materials. A treating physician should be aware of the advantages and limitations of these implants, which may influence the choice of one anchor over another. In addition to anchor variables, other factors that may affect the success of the repair include the local environment and surgical technique. In this article, various aspects of anchor design will be discussed. In addition, a concise review of technical considerations will also be discussed.
Similar articles
-
In vitro analysis of rotator cuff repairs: a comparison of arthroscopically inserted tacks or anchors with open transosseous repairs.Arthroscopy. 2005 Mar;21(3):323-7. doi: 10.1016/j.arthro.2004.11.018. Arthroscopy. 2005. PMID: 15756187
-
Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair.Clin Biomech (Bristol). 2007 Jan;22(1):106-11. doi: 10.1016/j.clinbiomech.2006.07.009. Epub 2006 Sep 25. Clin Biomech (Bristol). 2007. PMID: 16996666
-
Arthroscopic rotator cuff repair using the Opus knotless suture anchor fixation system.Am J Sports Med. 2009 Jun;37(6):1106-10. doi: 10.1177/0363546508331203. Epub 2009 Mar 16. Am J Sports Med. 2009. PMID: 19289542
-
Tissue anchor use in arthroscopic glenohumeral surgery.J Am Acad Orthop Surg. 2012 Jul;20(7):459-71. doi: 10.5435/JAAOS-20-07-459. J Am Acad Orthop Surg. 2012. PMID: 22751165 Review.
-
General surgical principles of open rotator cuff repair in the management of failed arthroscopic cuff repairs.Instr Course Lect. 2013;62:105-14. Instr Course Lect. 2013. PMID: 23395018 Review.
Cited by
-
Single-nucleus transcriptomics reveals subsets of degenerative myonuclei after rotator cuff tear-induced muscle atrophy.Cell Prolif. 2025 Mar;58(3):e13763. doi: 10.1111/cpr.13763. Epub 2024 Oct 22. Cell Prolif. 2025. PMID: 39435630 Free PMC article.
-
[Recurrent defects of the rotary cuff : Causes and therapeutic strategies].Oper Orthop Traumatol. 2012 Nov;24(6):458-67. doi: 10.1007/s00064-012-0179-2. Oper Orthop Traumatol. 2012. PMID: 23111442 Review. German.
-
Biomechanical properties of a suture anchor system from human allogenic mineralized cortical bone matrix for rotator cuff repair.BMC Musculoskelet Disord. 2022 May 5;23(1):422. doi: 10.1186/s12891-022-05371-0. BMC Musculoskelet Disord. 2022. PMID: 35513813 Free PMC article.
-
MR arthrography of the shoulder: tolerance evaluation of four different injection techniques.Skeletal Radiol. 2013 Jan;42(1):99-105. doi: 10.1007/s00256-012-1526-y. Epub 2012 Oct 14. Skeletal Radiol. 2013. PMID: 23064511 Clinical Trial.
-
Efficacy of management of associated dysfunctions on rotator cuff and long head of the biceps: systematic review.J Orthop Surg Res. 2021 Aug 16;16(1):501. doi: 10.1186/s13018-021-02621-0. J Orthop Surg Res. 2021. PMID: 34399799 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources