Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Apr;124(8):1199-204.

Efficiently tracking of stem cells in vivo using different kinds of superparamagnetic iron oxide in swine with myocardial infarction

Affiliations
  • PMID: 21542996

Efficiently tracking of stem cells in vivo using different kinds of superparamagnetic iron oxide in swine with myocardial infarction

Gen-shan Ma et al. Chin Med J (Engl). 2011 Apr.

Abstract

Background: Superparamagnetic iron oxide (SPIO) particles have shown much promise as a means to visualize labeled cells using molecular magnetic resonance imaging (MRI). Micrometer-sized superparamagnetic iron oxide (MPIO) particles and nanometer-sized ultrasmall superparamagnetic iron oxide (USPIO) are two kinds of SPIO widely used for monitoring stem cells migration. Here we compare the efficiency of two kinds of SPIO during the use of stem cells to treat acute myocardial infarction (AMI).

Methods: An AMI model in swine was created by 60 minutes of balloon occlusion of the left anterior descending coronary artery. Two kinds of SPIO particles were used to track after intracoronary delivered 10(7) magnetically labeled mesenchymal stem cells (MR-MSCs). The distribution and migration of the MR-MSCs were assessed with the use of 3.0T MR scanner and then the results were confirmed by histological examination.

Results: MR-MSCs appeared as a local hypointense signal on T₂*-weighted MRI and there was a gradual loss of the signal intensity after intracoronary transplantation. All of the hypointense signals in the USPIO-labeled group were found on T₂*-weighted MRI, contrast to noise ratio (CNR) decreased in the MPIO-labeled group (16.07 ± 5.85 vs. 10.96 ± 1.34) and USPIO-labeled group (11.72 ± 1.27 vs. 10.03 ± 0.96) from 4 to 8 weeks after transplantation. However, the hypointense signals were not detected in MPIO-labeled group in two animals. MRI and the results were verified by histological examination.

Conclusions: We demonstrated that two kinds of SPIO particles in vitro have similar labeling efficiency and viability. USPIO is more suitable for labeling stem cells when they are transplanted via a coronary route.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources