The quality of defibrillation performance among students of the University of Medical Sciences
- PMID: 21547553
- DOI: 10.1007/s00540-011-1158-8
The quality of defibrillation performance among students of the University of Medical Sciences
Abstract
The major objective was to assess the time period from a witnessed ventricular fibrillation (VF) to the first defibrillation (DEF) in a simulated manikin scenario, while the minor objective was to analyze the most common errors that occurred during DEF and the maintenance of 2-min intervals during resuscitation. We examined 210 students (medical faculty students, MF; and paramedic faculty students, PF) who had to treat a patient with VF. In the study we used the Laerdal(®) Training Manikin and the Zoll M Series(®) defibrillator. The mean time period from the witnessed VF to the first DEF was 50.1 s (SD 32.5 s) in the MF group and 62.9 s (SD 36.9 s) in the PF group (no statistically significant difference). The delay resulted from the lack of constant ECG monitoring and charging in the option "Monitor" instead of the option "Defibrillation." The PF group shortened the 2-min cycles between defibrillations. The problems observed during the study were technical and educational. We concluded that the option "Monitor" should be removed from the equipment because it seems to be redundant. The teaching problems were a lack of constant ECG monitoring, incorrect handling of the defibrillator, and not keeping to 2-min loops of CPR.
Similar articles
-
Mechanical LUCAS resuscitation is effective, reduces physical workload and improves mental performance of helicopter teams.Minerva Anestesiol. 2016 Apr;82(4):429-37. Epub 2015 Nov 17. Minerva Anestesiol. 2016. PMID: 26576860 Clinical Trial.
-
Early defibrillation by emergency physicians or emergency medical technicians? A controlled, prospective multi-centre study.Resuscitation. 1994 May;27(3):197-206. doi: 10.1016/0300-9572(94)90033-7. Resuscitation. 1994. PMID: 8079053 Clinical Trial.
-
Defibrillator charging before rhythm analysis causes peri-shock pauses exceeding guideline recommended maximum 5 s : A randomized simulation trial.Anaesthesist. 2019 Aug;68(8):546-554. doi: 10.1007/s00101-019-0623-x. Anaesthesist. 2019. PMID: 31332449 Review. English.
-
Double Sequential External Defibrillation and Survival from Out-of-Hospital Cardiac Arrest: A Case Report.Prehosp Emerg Care. 2016 Sep-Oct;20(5):662-6. doi: 10.3109/10903127.2016.1168891. Epub 2016 Apr 14. Prehosp Emerg Care. 2016. PMID: 27077941
-
[Analysis of ventricular fibrillation signals for the evaluation of defibrillation success in the treatment of ventricular fibrillation].Anasthesiol Intensivmed Notfallmed Schmerzther. 2003 Dec;38(12):787-94. doi: 10.1055/s-2003-45401. Anasthesiol Intensivmed Notfallmed Schmerzther. 2003. PMID: 14666442 Review. German.
Cited by
-
External defibrillation on an implantable defibrillator.J Anesth. 2014 Apr;28(2):312. doi: 10.1007/s00540-013-1710-9. Epub 2013 Oct 6. J Anesth. 2014. PMID: 24097168 No abstract available.
References
MeSH terms
LinkOut - more resources
Full Text Sources