Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jun;36(6):423-8.
doi: 10.1097/RLU.0b013e3182173823.

Impact of dual-time-point F-18 FDG PET/CT in the assessment of pleural effusion in patients with non-small-cell lung cancer

Affiliations

Impact of dual-time-point F-18 FDG PET/CT in the assessment of pleural effusion in patients with non-small-cell lung cancer

Khaled Alkhawaldeh et al. Clin Nucl Med. 2011 Jun.

Abstract

Aim: The aim of this study was to assess the utility of dual-time-point F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) in differentiating benign from malignant pleural disease, in patients with non-small-cell lung cancer.

Methods: A total of 61 patients with non-small-cell lung cancer and pleural effusion were included in this retrospective study. All patients had whole-body FDG PET/CT imaging at 60 ± 10 minutes post-FDG injection, whereas 31 patients had second-time delayed imaging repeated at 90 ± 10 minutes for the chest. Maximum standardized uptake values (SUV(max)) and the average percent change in SUV(max) (%SUV) between time point 1 and time point 2 were calculated. Malignancy was defined using the following criteria: (1) visual assessment using 3-points grading scale; (2) SUV(max) ≥2.4; (3) %SUV ≥ +9; and (4) SUV(max) ≥2.4 and/or %SUV ≥ +9. Analysis of variance test and receiver operating characteristic analysis were used in statistical analysis. P < 0.05 was considered significant.

Results: Follow-up revealed 29 patient with malignant pleural disease and 31 patients with benign pleural effusion. The average SUV(max) in malignant effusions was 6.5 ± 4 versus 2.2 ± 0.9 in benign effusions (P < 0.0001). The average %SUV in malignant effusions was +13 ± 10 versus -8 ± 11 in benign effusions (P < 0.0004). Sensitivity, specificity, and accuracy for the 5 criteria were as follows: (1) 86%, 72%, and 79%; (2) 93%, 72%, and 82%; (3) 67%, 94%, and 81%; (4) 100%, 94%, and 97%.

Conclusions: Dual-time-point F-18 FDG PET can improve the diagnostic accuracy in differentiating benign from malignant pleural disease, with high sensitivity and good specificity.

PubMed Disclaimer

Substances