Abstract
Purpose: To evaluate whether microbubbles targeted to vascular cell adhesion molecule-1 (VCAM-1) (CD106) coupled with a magnetic guidance system could improve the efficacy of contrast-enhanced molecular ultrasonography (US) of atherosclerosis in the aorta.
Materials and methods: The animal research committee at Southern Medical University approved all experiments. Adherence of magnetic VCAM-1-targeted microbubbles, control inactive magnetic microbubbles, and nonmagnetic VCAM-1-targeted microbubbles to VCAM-1-Fc was determined in vitro by using a flow chamber at variable shear stress (1-24 dyne/cm(2)) under magnetic field guidance. Attachment of microbubbles under magnetic field guidance was determined in vivo with fluorescent microscopy and contrast-enhanced US of the abdominal aorta in wild-type (C57BL/6) or apolipoprotein E (APOE)-deficient mice on a regular or hypercholesterolemic diet. General factorial analysis of variance was used to compare the targeted effect of the microbubbles among different animal groups to identify significant differences.
Results: Attachment was noted for magnetic and nonmagnetic microbubbles but not for inactive magnetic microbubbles; firm attachment at high shear stress (16-20 dyne/cm(2)) was achieved only with magnetic microbubbles. Fluorescence intensity and video intensity were significantly higher in magnetic microbubbles with magnetic field guidance than in inactive magnetic microbubbles and nonmagnetic microbubbles (P < .05). Video intensity from retained magnetic microbubbles in APOE-deficient mice was significantly greater than that in wild-type mice (mean video intensity for APOE-deficient mice: 28.25 [interquartile range, or IQR, 26.55-29.20] with a hypercholesterolemic diet and 16.10 [IQR, 14.15-18.75] with a regular diet; mean video intensity for wild-type mice: 9.55 [IQR, 8.85-10.5] with a hypercholesterolemic diet and 2.90 [IQR, 1.25-3.85] with a regular diet; P < .001).
Conclusion: Use of a magnetic targeted microbubble system results in greater attachment to endothelial VCAM-1 in atherosclerotic aortas in conditions of high shear stress and improved detection of early inflammatory changes of atherosclerosis.
© RSNA, 2011.
Comment in
-
Science to practice: will magnetic guidance of microbubbles play a role in clinical molecular imaging?Radiology. 2011 Aug;260(2):309-10. doi: 10.1148/radiol.11111017. Radiology. 2011. PMID: 21778448
Similar articles
-
Molecular imaging of inflammation in atherosclerosis with targeted ultrasound detection of vascular cell adhesion molecule-1.Circulation. 2007 Jul 17;116(3):276-84. doi: 10.1161/CIRCULATIONAHA.106.684738. Epub 2007 Jun 25. Circulation. 2007. PMID: 17592078
-
Science to practice: will magnetic guidance of microbubbles play a role in clinical molecular imaging?Radiology. 2011 Aug;260(2):309-10. doi: 10.1148/radiol.11111017. Radiology. 2011. PMID: 21778448
-
Molecular imaging reveals rapid reduction of endothelial activation in early atherosclerosis with apocynin independent of antioxidative properties.Arterioscler Thromb Vasc Biol. 2013 Sep;33(9):2187-92. doi: 10.1161/ATVBAHA.113.301710. Epub 2013 Aug 1. Arterioscler Thromb Vasc Biol. 2013. PMID: 23908248 Free PMC article.
-
Magnetic microbubbles conjugated with anti-vascular cell adhesion molecule-1 monoclonal antibody 429.2012 Feb 27 [updated 2012 Jun 14]. In: Molecular Imaging and Contrast Agent Database (MICAD) [Internet]. Bethesda (MD): National Center for Biotechnology Information (US); 2004–2013. 2012 Feb 27 [updated 2012 Jun 14]. In: Molecular Imaging and Contrast Agent Database (MICAD) [Internet]. Bethesda (MD): National Center for Biotechnology Information (US); 2004–2013. PMID: 22720336 Free Books & Documents. Review.
-
Molecular imaging of disease with targeted contrast ultrasound imaging.Transl Res. 2012 Mar;159(3):140-8. doi: 10.1016/j.trsl.2011.12.001. Epub 2012 Jan 4. Transl Res. 2012. PMID: 22340763 Free PMC article. Review.
Cited by
-
Nanobody-coupled microbubbles as novel molecular tracer.J Control Release. 2012 Mar 10;158(2):346-53. doi: 10.1016/j.jconrel.2011.12.007. Epub 2011 Dec 16. J Control Release. 2012. PMID: 22197777 Free PMC article.
-
Nanobubbles for enhanced ultrasound imaging of tumors.Int J Nanomedicine. 2012;7:895-904. doi: 10.2147/IJN.S28830. Epub 2012 Feb 22. Int J Nanomedicine. 2012. PMID: 22393289 Free PMC article.
-
Applications of magnetic microbubbles for theranostics.Theranostics. 2012;2(1):103-12. doi: 10.7150/thno.3464. Epub 2012 Jan 12. Theranostics. 2012. PMID: 22287990 Free PMC article.
-
Immunomodulatory nanosystems: An emerging strategy to combat viral infections.Biomater Biosyst. 2023 Jan 30;9:100073. doi: 10.1016/j.bbiosy.2023.100073. eCollection 2023 Mar. Biomater Biosyst. 2023. PMID: 36967725 Free PMC article. Review.
-
Circulating Magnetic Microbubbles for Localized Real-Time Control of Drug Delivery by Ultrasonography-Guided Magnetic Targeting and Ultrasound.Theranostics. 2018 Jan 1;8(2):341-357. doi: 10.7150/thno.20781. eCollection 2018. Theranostics. 2018. PMID: 29290812 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous