Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;260(2):463-71.
doi: 10.1148/radiol.11102251. Epub 2011 May 9.

Efficacy of contrast-enhanced US and magnetic microbubbles targeted to vascular cell adhesion molecule-1 for molecular imaging of atherosclerosis

Affiliations

Efficacy of contrast-enhanced US and magnetic microbubbles targeted to vascular cell adhesion molecule-1 for molecular imaging of atherosclerosis

Juefei Wu et al. Radiology. 2011 Aug.

Abstract

Purpose: To evaluate whether microbubbles targeted to vascular cell adhesion molecule-1 (VCAM-1) (CD106) coupled with a magnetic guidance system could improve the efficacy of contrast-enhanced molecular ultrasonography (US) of atherosclerosis in the aorta.

Materials and methods: The animal research committee at Southern Medical University approved all experiments. Adherence of magnetic VCAM-1-targeted microbubbles, control inactive magnetic microbubbles, and nonmagnetic VCAM-1-targeted microbubbles to VCAM-1-Fc was determined in vitro by using a flow chamber at variable shear stress (1-24 dyne/cm(2)) under magnetic field guidance. Attachment of microbubbles under magnetic field guidance was determined in vivo with fluorescent microscopy and contrast-enhanced US of the abdominal aorta in wild-type (C57BL/6) or apolipoprotein E (APOE)-deficient mice on a regular or hypercholesterolemic diet. General factorial analysis of variance was used to compare the targeted effect of the microbubbles among different animal groups to identify significant differences.

Results: Attachment was noted for magnetic and nonmagnetic microbubbles but not for inactive magnetic microbubbles; firm attachment at high shear stress (16-20 dyne/cm(2)) was achieved only with magnetic microbubbles. Fluorescence intensity and video intensity were significantly higher in magnetic microbubbles with magnetic field guidance than in inactive magnetic microbubbles and nonmagnetic microbubbles (P < .05). Video intensity from retained magnetic microbubbles in APOE-deficient mice was significantly greater than that in wild-type mice (mean video intensity for APOE-deficient mice: 28.25 [interquartile range, or IQR, 26.55-29.20] with a hypercholesterolemic diet and 16.10 [IQR, 14.15-18.75] with a regular diet; mean video intensity for wild-type mice: 9.55 [IQR, 8.85-10.5] with a hypercholesterolemic diet and 2.90 [IQR, 1.25-3.85] with a regular diet; P < .001).

Conclusion: Use of a magnetic targeted microbubble system results in greater attachment to endothelial VCAM-1 in atherosclerotic aortas in conditions of high shear stress and improved detection of early inflammatory changes of atherosclerosis.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources