. 2011 Apr;32(3):68-73.

Evaluation of cleansing methods for previously worn prostheses

Affiliations
  • PMID: 21560745

Evaluation of cleansing methods for previously worn prostheses

R Thomas Glass et al. Compend Contin Educ Dent. 2011 Apr.

Abstract

Statement of problem: Although there are many product claims that address the issue of denture sanitization, controlled scientific studies on previously worn dentures have not been performed.

Purpose: The purpose of this study was to evaluate procedures directed at sanitizing previously worn contaminated dentures from two regions of the United States.

Materials and methods: This study examined 51 previously worn dentures from two regions. An established method of denture retrieval, sectioning, and culturing was used, including isolation of anaerobes. Evaluation of microbial contamination posttreatment was used to determine the effects of soaking dentures in Polident (US and European formulations) for varying periods of times/temperatures, microwaving dentures with varying temperatures, sonicating dentures, and immersing the dentures while using a vacuum. A combination of analysis of variance (ANOVA) and general linear model (GLM) of the SPSS was used to analyze the data with P < .05 being considered statistically significant when using a two-tailed test.

Results: While all Polident treatments were found to significantly reduce microorganism loads in dentures, extended soaking (8 hours) and 65 degrees C (5 minutes) were the most effective. Microwaving was slightly more effective than either sonication or vacuum. Regardless the treatment, dentures underwent sanitization rather than sterilization.

Conclusions: Denture-borne microorganisms can be significantly reduced by using a Polident solution for 8 hours at room temperature or for 5 minutes at 65 degrees C. Microwaving, sonication, and use of a vacuum were less effective. ClLINICAL IMPLICATIONS The importance of daily use of Polident solution for 8 hours or for 5 minutes at 65 degrees C to sanitize worn prostheses must be stressed.

PubMed Disclaimer