Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2011 Apr;22(4):445-54.
doi: 10.1111/j.1600-0501.2010.02125.x.

Immediately restored single implants in the aesthetic zone of the maxilla using a novel design: 1-year report

Affiliations
Clinical Trial

Immediately restored single implants in the aesthetic zone of the maxilla using a novel design: 1-year report

Simon D K Brown et al. Clin Oral Implants Res. 2011 Apr.

Abstract

Objectives: To evaluate immediate placement and immediate restoration of a novel implant with a 12°-angled prosthodontic platform, in fresh extraction sockets of the aesthetic zone of the maxilla.

Materials and methods: Tapered, roughened surface implants of 4 mm (n=15) or 5 mm (n=13) diameter were placed in 27 participants (mean age: 47.1 years; range: 21-71 years) requiring an immediate replacement of single anterior maxillary teeth. Provisional screw-retained all-ceramic crowns were placed within 4 h following optical impressions. At 8 weeks (baseline), definitive screw-retained all-ceramic crowns were placed in occlusion.

Results: Twenty-six of the 28 implants met the inclusion criteria at surgery. Marginal bone levels revealed bone gain between surgery and baseline, and between baseline and 1 year of 0.2 mm (SD 0.75) and 0.78 mm (SD 2.45). Mean mid-buccal mucosal margins showed gains of 0.2 mm (SD 0.44). Prosthodontic maintenance and the aesthetics of the screw-retained implant crowns were facilitated by the external hex 12°-angled prosthodontic platform on the novel implant design, re-orientating the access cavity to the palatal or occlusal surfaces. All-ceramic implant crowns showed a high success rate with low maintenance issues over 1 year.

Conclusion: Tapered, roughened-surfaced implants with a novel 12°-angled prosthodontic platform immediately placed in fresh extraction sockets, immediately restored with provisional crowns and subsequent definitive crowns at 8 weeks were successful for 1 year.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources