The role of ultrahigh-frequency audiometry in the early detection of systemic drug-induced hearing loss
- PMID: 21563089
- DOI: 10.1177/014556131109000506
The role of ultrahigh-frequency audiometry in the early detection of systemic drug-induced hearing loss
Abstract
In monitoring patients for drug-induced hearing loss, most audiometric evaluations are limited to the range of frequencies from 0.25 to 8 kHz. However, such testing would fail to detect ototoxicity in patients who have already experienced hearing loss in the ultrahigh frequencies from 10 to 20 kHz. Awareness of ultrahigh-frequency ototoxicity could lead to changes in a drug regimen to prevent further damage. We conducted a prospective study of 105 patients who were receiving a potentially ototoxic drug-either gentamicin, amikacin, or cisplatin-to assess the value of ultrahigh-frequency audiometry in detecting systemic drug-induced hearing loss. We found that expanding audiometry into the ultrahigh-frequency range led to the detection of a substantial number of cases of hearing loss that would have otherwise been missed.
Similar articles
-
High-frequency audiometric monitoring for early detection of aminoglycoside ototoxicity.J Infect Dis. 1992 Jun;165(6):1026-32. doi: 10.1093/infdis/165.6.1026. J Infect Dis. 1992. PMID: 1583319
-
Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.Ear Hear. 2008 Dec;29(6):875-93. doi: 10.1097/AUD.0b013e318181ad99. Ear Hear. 2008. PMID: 18753950 Clinical Trial.
-
The Role of Audiometry prior to High-Dose Cisplatin in Patients with Head and Neck Cancer.Oncology. 2017;93(2):75-82. doi: 10.1159/000468522. Epub 2017 May 17. Oncology. 2017. PMID: 28511189 Clinical Trial.
-
Ototoxic Drug Exposure and Hearing Loss in Neonates: A Scoping Review.Am J Audiol. 2024 Dec 2;33(4):1356-1377. doi: 10.1044/2024_AJA-24-00065. Epub 2024 Sep 23. Am J Audiol. 2024. PMID: 39312737
-
Ototoxicity.Kidney Int. 2007 Oct;72(8):931-5. doi: 10.1038/sj.ki.5002434. Epub 2007 Jul 25. Kidney Int. 2007. PMID: 17653135 Review.
Cited by
-
Effect of Blood Group on Ultrahigh Frequency Auditory Sensitivity.Int Arch Otorhinolaryngol. 2018 Oct;22(4):364-367. doi: 10.1055/s-0037-1613711. Epub 2017 Dec 15. Int Arch Otorhinolaryngol. 2018. PMID: 30357092 Free PMC article.
-
Comparing amikacin and kanamycin-induced hearing loss in multidrug-resistant tuberculosis treatment under programmatic conditions in a Namibian retrospective cohort.BMC Pharmacol Toxicol. 2015 Dec 10;16:36. doi: 10.1186/s40360-015-0036-7. BMC Pharmacol Toxicol. 2015. PMID: 26654443 Free PMC article.
-
Extended high-frequency audiometry in healthy adults with different age groups.J Otolaryngol Head Neck Surg. 2021 Aug 26;50(1):52. doi: 10.1186/s40463-021-00534-w. J Otolaryngol Head Neck Surg. 2021. PMID: 34446093 Free PMC article.
-
A Review of Cisplatin-Associated Ototoxicity.Semin Hear. 2019 May;40(2):108-121. doi: 10.1055/s-0039-1684041. Epub 2019 Apr 26. Semin Hear. 2019. PMID: 31036989 Free PMC article. Review.
-
Noise Pollution and Associated Hearing Loss in a Metropolitan City-a Preliminary Report.Indian J Otolaryngol Head Neck Surg. 2023 Apr;75(Suppl 1):278-284. doi: 10.1007/s12070-022-03432-3. Epub 2022 Dec 29. Indian J Otolaryngol Head Neck Surg. 2023. PMID: 37206820 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical