Noncardiac entrapment of a pulmonary artery catheter during heart transplantation: inadvertent cannulation and perforation of the internal thoracic vein
- PMID: 21570620
- DOI: 10.1016/j.jclinane.2010.03.010
Noncardiac entrapment of a pulmonary artery catheter during heart transplantation: inadvertent cannulation and perforation of the internal thoracic vein
Abstract
Placement of a central venous catheter into an internal thoracic vein occurs in approximately 2% of all catheterizations. A case in which a pulmonary artery catheter was trapped within the internal thoracic vein during orthotopic heart transplantation is presented.
Copyright © 2011 Elsevier Inc. All rights reserved.