Two-dimensional phase correction method for single and multi-shot echo planar imaging
- PMID: 21574178
- DOI: 10.1002/mrm.22958
Two-dimensional phase correction method for single and multi-shot echo planar imaging
Abstract
Ghost artifacts are a serious issue in single and multi-shot echo planar imaging. Because of these coherent artifacts, it is essential to consistently suppress the ghosts. In this article, we present a phase correction algorithm that achieves excellent ghost suppression for single and multi-shot echo planar imaging. The phase correction is performed along both the x (read) direction and y (phase) direction. To this end, we apply a double field of view prescan and compute the phase required for ghost suppression. This phase is fitted to a 2D polynomial. The fitted phase is used to correct the echo planar imaging images. The correction algorithm can be used with any readout gradient polarities and any number of shots. A flow chart of the correction method is provided to better clarify the full process. Finally, phantom and volunteer images demonstrate the improvement of artifact suppression obtained with this algorithm over conventional phase correction methods.
Copyright © 2011 Wiley Periodicals, Inc.
Similar articles
-
Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.Magn Reson Med. 2005 Dec;54(6):1412-22. doi: 10.1002/mrm.20706. Magn Reson Med. 2005. PMID: 16276497
-
Robust 2D phase correction for echo planar imaging under a tight field-of-view.Magn Reson Med. 2010 Dec;64(6):1800-13. doi: 10.1002/mrm.22577. Epub 2010 Aug 30. Magn Reson Med. 2010. PMID: 20806354
-
Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction.Magn Reson Med. 2013 Jun;69(6):1650-6. doi: 10.1002/mrm.24396. Epub 2012 Jul 17. Magn Reson Med. 2013. PMID: 22807105
-
A hybrid strategy for correcting geometric distortion in echo-planar images.Magn Reson Imaging. 2014 Jun;32(5):590-3. doi: 10.1016/j.mri.2014.02.011. Epub 2014 Feb 14. Magn Reson Imaging. 2014. PMID: 24650682
-
Imaging the knee in the setting of metal hardware.Magn Reson Imaging Clin N Am. 2014 Nov;22(4):765-86. doi: 10.1016/j.mric.2014.07.009. Epub 2014 Aug 28. Magn Reson Imaging Clin N Am. 2014. PMID: 25442032 Review.
Cited by
-
Combining multiband slice selection with consistent k-t-space EPSI for accelerated spectral imaging.Magn Reson Med. 2019 Sep;82(3):867-876. doi: 10.1002/mrm.27767. Epub 2019 Apr 16. Magn Reson Med. 2019. PMID: 30990227 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources