[Corrosion property and oxide film of dental casting alloys before and after porcelain firing]
- PMID: 21575441
[Corrosion property and oxide film of dental casting alloys before and after porcelain firing]
Abstract
Objective: To evaluate the types and compositions of oxide films formed during porcelain-fused-to-metal (PFM) firing on three kinds of dental casting alloys, and to investigate the corrosion property of these alloys in Dulbecco's modification of Eagle's medium (DMEM) cell culture fluid, before and after PFM firing.
Methods: Specimens of three dental casting alloys (Ni-Cr, Co-Cr and Ni-Ti) before and after PFM firing were prepared, and were immersed in DMEM cell culture fluid. After 30 days, the type and concentration of released metal ions were measured using inductively coupled plasma atomic emission spectroscopy (ICP-AES). X-ray photoelectron spectroscopy (XPS) and scanning electron microscope (SEM) were used for analysis of oxide film on the alloys. One way-ANOVA was adopted in data analysis.
Results: The total amount of metal ions released from the three dental alloys was found to be highest in Ni-Cr alloy [(2.829 ± 0.694) mg/L], followed by Co-Cr [(2.120 ± 0.418) mg/L] and Ni-Ti alloy [(1.211 ± 0.101) mg/L]. The amount of Ni ions released from Ni-Cr alloys [(1.531 ± 0.392) mg/L] was higher than that from Ni-Ti alloys [(0.830 ± 0.052) mg/L]. The amount of Cr, Mo ions released from Co-Cr alloy [Cr: (0.048 ± 0.011) mg/L, Mo: (1.562 ± 0.333) mg/L] was higher than that from Ni-Cr alloy [Cr: (0.034 ± 0.002) mg/L, Mo: (1.264 ± 0.302) mg/L] and Ni-Ti alloy [Cr: (0.013 ± 0.006) mg/L, Mo: (0.151 ± 0.026) mg/L] (P < 0.05). After PFM firing, the total amount of metal irons released from the three dental alloys decreased [Ni-Cr: (0.861 ± 0.054) mg/L, Co-Cr: (0.695 ± 0.327) mg/L, Ni-Ti: (0.892 ± 0.115) mg/L] (P < 0.05). In addition, XPS showed increase of Cr(2)O(3) and Mo-Ni oxide on the surface of all the alloys after PFM firing.
Conclusions: The amount of ions released from Ni-Cr alloy was the highest among the three dental casting alloys, this means Ni-Cr alloy is prone to corrode. The PFM firing process changed the alloys' surface composition. Increased Ni, Cr and Mo were found in oxide film, and the increase in Cr(2)O(3) can improve the corrosion-resistance of alloys.
Similar articles
-
Corrosion behaviour and surface analysis of a Co-Cr and two Ni-Cr dental alloys before and after simulated porcelain firing.Eur J Oral Sci. 2011 Feb;119(1):93-101. doi: 10.1111/j.1600-0722.2011.00791.x. Eur J Oral Sci. 2011. PMID: 21244518
-
Metallurgical, surface, and corrosion analysis of Ni-Cr dental casting alloys before and after porcelain firing.Dent Mater. 2008 Mar;24(3):378-85. doi: 10.1016/j.dental.2007.06.010. Epub 2007 Aug 15. Dent Mater. 2008. PMID: 17706759
-
Use of x-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused-to-metal firing.J Prosthet Dent. 2000 Dec;84(6):623-34. doi: 10.1067/mpr.2000.111496. J Prosthet Dent. 2000. PMID: 11125349
-
Biocompatibility of dental casting alloys: a review.J Prosthet Dent. 2000 Feb;83(2):223-34. doi: 10.1016/s0022-3913(00)80016-5. J Prosthet Dent. 2000. PMID: 10668036 Review.
-
[Research progress in CoCr metal-ceramic alloy fabricated by selective laser melting].Zhonghua Kou Qiang Yi Xue Za Zhi. 2018 Feb 9;53(2):141-144. doi: 10.3760/cma.j.issn.1002-0098.2018.02.017. Zhonghua Kou Qiang Yi Xue Za Zhi. 2018. PMID: 29429239 Review. Chinese.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources