Elevated laser flare values correlate with complicated course of anterior uveitis in patients with juvenile idiopathic arthritis
- PMID: 21586097
- DOI: 10.1111/j.1755-3768.2011.02162.x
Elevated laser flare values correlate with complicated course of anterior uveitis in patients with juvenile idiopathic arthritis
Abstract
Purpose: To evaluate the prognostic value of anterior chamber (AC) laser flare (LF) in uveitis associated with juvenile idiopathic arthritis (JIA).
Methods: Monocentre, retrospective study of 150 JIA children (girls n = 107, 71.3%) with unilateral or bilateral chronic anterior uveitis (statistical analysis of one eye per patient). LF values (KOWA FM-500), visual acuity, intraocular pressure, glaucoma treatment and uveitis complications were investigated longitudinally.
Results: Patients were followed up for a mean of 8.7 months (range 1-36). High LF values correlated with poor visual acuity (p < 0.0001). Patients with low LF values (LF ≤ 20 photon units per millisecond) less often required glaucoma medication (p = 0.0005) or surgery (p = 0.01) and showed a lower prevalence of cataract, band keratopathy, posterior synechiae, epiretinal membrane, optic disc oedema and glaucoma/ocular hypertension (p < 0.05, each). Baseline LF > 20 photon units per millisecond was a better prognosticator for the development of subsequent complications than baseline AC cells (p = 0.04).
Conclusions: High LF values in patients with JIA uveitis are associated with poor vision and a higher prevalence of uveitis complications.
© 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.