Accurate assessment of breast volume: a study comparing the volumetric gold standard (direct water displacement measurement of mastectomy specimen) with a 3D laser scanning technique
- PMID: 21587046
- DOI: 10.1097/SAP.0b013e31820ebdd0
Accurate assessment of breast volume: a study comparing the volumetric gold standard (direct water displacement measurement of mastectomy specimen) with a 3D laser scanning technique
Abstract
Preoperative assessment of breast volume could contribute significantly to the planning of breast-related procedures. The availability of 3D scanning technology provides us with an innovative method for doing this. We performed this study to compare measurements by this technology with breast volume measurement by water displacement. A total of 30 patients undergoing 39 mastectomies were recruited from our center. The volume of each patient's breast(s) was determined with a preoperative 3D laser scan. The volume of the mastectomy specimen was then measured in the operating theater by water displacement. There was a strong linear association between breast volumes measured using the 2 different methods when using a Pearson correlation (r = 0.95, P < 0.001). The mastectomy mean volume was defined by the equation: mastectomy mean volume = (scan mean volume × 1.03) -70.6. This close correlation validates the Cyberware WBX Scanner as a tool for assessment of breast volume.
Similar articles
-
Measurement of breast volume using body scan technology(computer-aided anthropometry).Work. 2012;41 Suppl 1:4038-45. doi: 10.3233/WOR-2012-0068-4038. Work. 2012. PMID: 22317340
-
Comparison between breast volume measurement using 3D surface imaging and classical techniques.Breast. 2007 Apr;16(2):137-45. doi: 10.1016/j.breast.2006.08.001. Epub 2006 Oct 6. Breast. 2007. PMID: 17029808
-
Breast volumetry using a three-dimensional surface assessment technique.Aesthetic Plast Surg. 2011 Oct;35(5):847-55. doi: 10.1007/s00266-011-9708-x. Epub 2011 Apr 13. Aesthetic Plast Surg. 2011. PMID: 21487916
-
Volumetric assessment of lower limb oedema using 3D laser scanning technique: a systematic review.J Med Eng Technol. 2022 Jan;46(1):40-45. doi: 10.1080/03091902.2021.1970841. Epub 2021 Oct 14. J Med Eng Technol. 2022. PMID: 34647841
-
Surgical embryology and anatomy of the breast and its related anatomic structures.Surg Clin North Am. 1993 Aug;73(4):611-32. doi: 10.1016/s0039-6109(16)46077-9. Surg Clin North Am. 1993. PMID: 8378813 Review.
Cited by
-
"Topographic Shift": a new digital approach to evaluating topographic changes of the female breast.Arch Gynecol Obstet. 2021 Feb;303(2):515-520. doi: 10.1007/s00404-020-05837-3. Epub 2020 Oct 20. Arch Gynecol Obstet. 2021. PMID: 33079242 Free PMC article.
-
Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study.Arch Plast Surg. 2016 Sep;43(5):430-7. doi: 10.5999/aps.2016.43.5.430. Epub 2016 Sep 21. Arch Plast Surg. 2016. PMID: 27689050 Free PMC article.
-
Women with larger breasts are less satisfied with their breasts: Implications for quality of life and physical activity participation.Womens Health (Lond). 2022 Jan-Dec;18:17455057221109394. doi: 10.1177/17455057221109394. Womens Health (Lond). 2022. PMID: 35801682 Free PMC article.
-
Intraoperative 3D Comparison of Round and Anatomical Breast Implants: Dispelling a Myth.J Clin Med. 2021 Dec 28;11(1):149. doi: 10.3390/jcm11010149. J Clin Med. 2021. PMID: 35011890 Free PMC article.
-
Effects of obesity on breast size, thoracic spine structure and function, upper torso musculoskeletal pain and physical activity in women.J Sport Health Sci. 2020 Mar;9(2):140-148. doi: 10.1016/j.jshs.2019.05.003. Epub 2019 May 9. J Sport Health Sci. 2020. PMID: 32099722 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical