Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Aug;8(5):409-15.
doi: 10.1007/s11739-011-0625-4. Epub 2011 May 18.

Lung ultrasonography for the assessment of rapid extravascular water variation: evidence from hemodialysis patients

Affiliations

Lung ultrasonography for the assessment of rapid extravascular water variation: evidence from hemodialysis patients

Matteo Trezzi et al. Intern Emerg Med. 2013 Aug.

Abstract

Chest ultrasonography is a useful tool to assess extravascular lung water at bedside. In presence of interstitial-alveolar imbibition, vertical artifacts arising from the pleura are detected; these are called B-lines. Although a positive linear correlation between B-lines and extravascular lung water has been shown in symptomatic heart failure patients, the subclinical phase of pulmonary imbibition and the clearance of B-lines after rapid body fluid removal have been less investigated. The aim of this study was to assess if chest ultrasound could detect lung water imbibition and its variations induced by dialysis, an experimental model of controlled rapid fluid loss. Forty-one patients undergoing hemodialysis were studied. Total number of B-lines from ultrasound chest scanning and vena cava diameters were measured before and after treatment. Before dialysis, most of the patients presented ultrasound signs of pulmonary imbibition despite the absence of dyspnea; the number of B-lines was associated with the accumulated weight before treatment (p < 0.05) as well as with the residual weight after dialysis (p < 0.01); B-lines and end-inspiratory and end-expiratory vena cava diameters were also significantly reduced after dialysis. Moreover, B-lines reduction was significantly related to weight loss. Ultrasound performed at the bedside can detect lung water and intravascular overload and their reduction after dialysis in yet asymptomatic patients. These observations add further evidence regarding the use of lung ultrasound and inferior vena cava measurement in estimating volume overload and monitoring the response to therapy both in hemodialysis and congestive heart failure patients.

PubMed Disclaimer

Comment in

  • Lung ultrasound imaging in haemodialysis.
    Vitturi N, Simoni F, Soattin M, Maresca L, Dugo M. Vitturi N, et al. Intern Emerg Med. 2013 Feb;8(1):87-8. doi: 10.1007/s11739-012-0831-8. Epub 2012 Jul 29. Intern Emerg Med. 2013. PMID: 22843333 No abstract available.

References

    1. Rheumatology (Oxford). 2009 Nov;48(11):1382-7 - PubMed
    1. Eur J Heart Fail. 2008 Jan;10(1):70-7 - PubMed
    1. Nephrol Dial Transplant. 2001 Jun;16(6):1203-6 - PubMed
    1. Am J Respir Crit Care Med. 1997 Nov;156(5):1640-6 - PubMed
    1. Circulation. 2009 Feb 10;119(5):671-9 - PubMed

LinkOut - more resources