Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor profile
- PMID: 21593742
- DOI: 10.1038/hr.2011.53
Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor profile
Abstract
The ankle-brachial index (ABI) is a method used widely for peripheral arterial disease (PAD) diagnosis and cardiovascular risk prediction. This study validated automated ABI measurements taken using an oscillometric blood pressure (BP) monitor allowing simultaneous arm-leg BP measurements. A total of 93 patients (hypertension 83%; dyslipidemia 72%; diabetes 45%; cardiovascular disease 23%; smoking 15%) were submitted to Doppler and automated ABI measurements, performed using a professional oscillometric BP monitor (Microlife WatchBP Office; triplicate simultaneous arm-leg BP measurements), in a randomized order. The mean difference between the Doppler reading (1.08 ± 0.17) and (1) the first oscillometric ABI reading was 0.03 ± 0.11, (2) the average of two oscillometric readings was 0.02 ± 0.10 and (3) the average of three oscillometric readings was 0.02 ± 0.09 (P < 0.01 for all). Strong correlations were found between oscillometric and Doppler ABI (r 0.80, 0.85 and 0.86 for single and average of two and three oscillometric readings, respectively; P < 0.001 for all). Agreement between oscillometric and Doppler ABI in diagnosing PAD (Doppler ABI < 0.9) was found in 95% of cases (κ 0.79; agreement in diabetics: 94%, κ 0.79). A receiver operating characteristic (ROC) curve revealed area under the curve at 0.98, with a 0.97 oscillometric ABI cutoff for optimal sensitivity (92%) and specificity (92%) in diagnosing PAD. Average time for automated ABI measurement was 5.8 vs. 9.3 min for Doppler (P < 0.001). Doppler and oscillometric ABI were associated and predicted (multivariate regression analysis) by the same cardiovascular risk factors (pulse pressure, smoking and cardiovascular disease history). Automated ABI measurement using a professional BP monitor allowing simultaneous arm-leg BP measurements appears to be a reliable and faster alternative to Doppler measurement.
Similar articles
-
Detection of peripheral arterial disease with an improved automated device: comparison of a new oscillometric device and the standard Doppler method.Vasc Health Risk Manag. 2016 Jul 29;12:305-11. doi: 10.2147/VHRM.S106534. eCollection 2016. Vasc Health Risk Manag. 2016. PMID: 27536125 Free PMC article.
-
Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease.Hypertens Res. 2013 Jan;36(1):25-8. doi: 10.1038/hr.2012.120. Epub 2012 Aug 9. Hypertens Res. 2013. PMID: 22875071 Clinical Trial.
-
[The potential role of oscillometric devices for ankle-brachial index measurements in clinical practice].Orv Hetil. 2018 Feb;159(5):176-182. doi: 10.1556/650.2018.30957. Orv Hetil. 2018. PMID: 29376424 Hungarian.
-
Automated oscillometric determination of the ankle-brachial index: a systematic review and meta-analysis.Hypertens Res. 2012 Sep;35(9):883-91. doi: 10.1038/hr.2012.83. Epub 2012 Jun 28. Hypertens Res. 2012. PMID: 22739420
-
Four-Limb Blood Pressure Measurement with an Oscillometric Device: a Tool for Diagnosing Peripheral Vascular Disease.Curr Hypertens Rep. 2019 Feb 12;21(2):15. doi: 10.1007/s11906-019-0917-z. Curr Hypertens Rep. 2019. PMID: 30747289 Review.
Cited by
-
Automated Measurements of Ankle-Brachial Index: A Narrative Review.J Clin Med. 2021 Nov 3;10(21):5161. doi: 10.3390/jcm10215161. J Clin Med. 2021. PMID: 34768679 Free PMC article. Review.
-
Automated plethysmographic measurement of the ankle-brachial index: a comparison with the doppler ultrasound method.Hypertens Res. 2016 Feb;39(2):100-6. doi: 10.1038/hr.2015.124. Epub 2015 Dec 3. Hypertens Res. 2016. PMID: 26631853
-
The Validity and Reliability between Automated Oscillometric Measurement of Ankle-Brachial Index and Standard Measurement by Eco-Doppler in Diabetic Patients with or without Diabetic Foot.Int J Endocrinol. 2017;2017:2383651. doi: 10.1155/2017/2383651. Epub 2017 May 9. Int J Endocrinol. 2017. PMID: 28572819 Free PMC article.
-
Detection of peripheral arterial disease with an improved automated device: comparison of a new oscillometric device and the standard Doppler method.Vasc Health Risk Manag. 2016 Jul 29;12:305-11. doi: 10.2147/VHRM.S106534. eCollection 2016. Vasc Health Risk Manag. 2016. PMID: 27536125 Free PMC article.
-
The reliability of the ankle brachial index: a systematic review.J Foot Ankle Res. 2019 Aug 2;12:39. doi: 10.1186/s13047-019-0350-1. eCollection 2019. J Foot Ankle Res. 2019. PMID: 31388357 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical