Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2011 Jun;187(6):357-66.
doi: 10.1007/s00066-011-2221-y. Epub 2011 May 16.

Interobserver variability of clinical target volume delineation in supra-diaphragmatic Hodgkin's disease: a multi-institutional experience

Affiliations
Multicenter Study

Interobserver variability of clinical target volume delineation in supra-diaphragmatic Hodgkin's disease: a multi-institutional experience

Domenico Genovesi et al. Strahlenther Onkol. 2011 Jun.

Abstract

Background: To determine interobserver variability in clinical target volume (CTV) of supra-diaphragmatic Hodgkin's lymphoma.

Materials and methods: At the 2008 AIRO (Italian Society of Radiation Oncology) Meeting, the Radiation Oncology Department of Chieti proposed a multi-institutional contouring dummy-run of two cases of early stage supra-diaphragmatic Hodgkin's lymphoma after chemotherapy. Clinical history, diagnostics, and planning CT imaging were available on Chieti's radiotherapy website (www.radioterapia.unich.it). Participating centers were requested to delineate the CTV and submit it to the coordinating center. To quantify interobserver variability of CTV delineations, the total volume, craniocaudal, laterolateral, and anteroposterior diameters were calculated.

Results: A total of 18 institutions for case A and 15 institutions for case B submitted the targets. Case A presented significant variability in total volume (range: 74.1-1,157.1 cc), craniocaudal (range: 6.5-22.5 cm; median: 16.25 cm), anteroposterior (range: 5.04-14.82 cm; median: 10.28 cm), and laterolateral diameters (range: 8.23-22.88 cm; median: 15.5 cm). Mean CTV was 464.8 cc (standard deviation: 280.5 cc). Case B presented significant variability in total volume (range: 341.8-1,662 cc), cranio-caudal (range: 8.0-28.5 cm; median: 23 cm), anteroposterior (range: 7.9-1.8 cm; median: 11.1 cm), and laterolateral diameters (range: 12.9-24.0 cm; median: 18.8 cm). Mean CTV was 926.0 cc (standard deviation: 445.7 cc).

Conclusion: This significant variability confirms the need to apply specific guidelines to improve contouring uniformity in Hodgkin's lymphoma.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann Oncol. 2009 Apr;20(4):767-74 - PubMed
    1. Ann Thorac Surg. 1994 Jul;58(1):158-62 - PubMed
    1. AJR Am J Roentgenol. 1998 Apr;170(4):927-31 - PubMed
    1. Ann Oncol. 2008 May;19 Suppl 2:ii65-6 - PubMed
    1. Behav Res Methods. 2007 Nov;39(4):755-66 - PubMed

Publication types

LinkOut - more resources