Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Sep;90(9):997-1004.
doi: 10.1111/j.1600-0412.2011.01197.x. Epub 2011 Jun 27.

Assessment of pain in women randomly allocated to speculum or digital insertion of the Foley catheter for induction of labor

Affiliations
Free article
Randomized Controlled Trial

Assessment of pain in women randomly allocated to speculum or digital insertion of the Foley catheter for induction of labor

Maria Jonsson et al. Acta Obstet Gynecol Scand. 2011 Sep.
Free article

Abstract

Objective: The primary aim was to assess pain subjectively and objectively in women during insertion of a Foley catheter for induction of labor. A secondary aim was to assess pain during cervical ripening and to evaluate maternal satisfaction.

Design: Randomized controlled trial.

Setting: University hospital, Sweden.

Population: Forty-two women undergoing induction of labor and cervical ripening with a Foley catheter.

Methods: Women were randomly allocated to digital (n=21) or to speculum (n=21) placement of a Foley catheter. A visual analogue scale (VAS) was used for subjective assessment of pain and, for objective measurements, a skin conductance algesimeter was used and the area under the curve (AUC) was calculated (μSs). Maternal satisfaction was evaluated in a questionnaire.

Main outcome measures: Pain sensation during placement of the Foley catheter.

Results: There was a significant difference between groups in pain measurements during insertion of the Foley catheter. The speculum group had higher median pain scores than the digital group, VAS=5 vs. = 3 (p=0.03) and greater median AUC measurements: 1840 vs. 823 μSs (p=0.04). There was no difference in pain assessments during cervical ripening. Overall satisfaction scores were high and comparable between groups.

Conclusion: Digital placement of the Foley catheter is subjectively and objectively less painful compared to the use of a speculum. Digital placement should therefore be considered as an alternative in the management of these patients. Ripening of the cervix with the Foley catheter is well tolerated and the overall satisfaction rate among patients induced with this method is high.

PubMed Disclaimer

Publication types