Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jul 1;1218(26):4039-44.
doi: 10.1016/j.chroma.2011.04.027. Epub 2011 Apr 16.

On-chip solid phase extraction and enzyme digestion using cationic PolyE-323 coatings and porous polymer monoliths coupled to electrospray mass spectrometry

Affiliations

On-chip solid phase extraction and enzyme digestion using cationic PolyE-323 coatings and porous polymer monoliths coupled to electrospray mass spectrometry

Yujuan Hua et al. J Chromatogr A. .

Abstract

We evaluate the compatibility and performance of polymer monolith solid phase extraction beds that incorporate cationic charge, with a polycationic surface coating, PolyE-323, fabricated within microfluidic glass chips. The PolyE-323 is used to reduce protein and peptide adsorption on capillary walls during electrophoresis, and to create anodal flow for electrokinetically driven nano-electrospray ionization mass spectrometry. A hydrophobic butyl methacrylate-based monolithic porous polymer was copolymerized with an ionizable monomer, [2-(methacryloyloxy)ethyl] trimethylammonium chloride to form a polymer monolith for solid phase extraction that also sustains anodal electroosmotic flow. Exposure of the PolyE-323 coating to the monolith forming mixture affected the performance of the chip by a minor amount; electrokinetic migration times increased by ∼5%, and plate numbers were reduced by an average of 5% for proteins and peptides. 1-mm long on-chip monolithic solid phase extraction columns showed reproducible, linear calibration curves (R(2)=0.9978) between 0.1 and 5 nM BODIPY at fixed preconcentration times, with a capacity of 2.4 pmol or 0.92 mmol/L of monolithic column for cytochrome c. Solution phase on-bed trypsin digestion was conducted by capturing model protein samples onto the monolithic polymer bed. Complete digestion of the proteins was recorded for a 30 min stop flow digestion, with high sequence coverage (88% for cytochrome c and 56% for BSA) and minimal trypsin autodigestion product. The polycationic coating and the polymer monolith materials proved to be compatible with each other, providing a high quality solid phase extraction bed and a robust coating to reduce protein adsorption and generate anodal flow, which is advantageous for electrospray.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources